The moment you can see beyond the imaginable.

This is the moment we work for.

doctors using opmi lumera 700 monitor surgery
doctors with gum shield
doctor and patient smiling

OPMI Lumera 700

The perfect microscope for cataract and retina surgery

OPMI Lumera 700 surgery microscope

Teaser get touch

Contact

The right contact person for your request

Locations & Contact Numbers
Contact form
Service Contact

OPMI LUMERA 700 and RESCAN 700 from ZEISS

Now with integrated intraoperative OCT

OPMI LUMERA 700 and RESCAN 700

A new dimension in visualization

Innovation in eye care starts with the desire to see more. With the first surgical microscope and the first commercial OCT for ophthalmic applications, two gold standards have now been fused together into one system – ushering in a new era of surgical microscopes.

 

See more:

  • during surgery
  • with real-time HD-OCT
  • for better decision making

ZEISS RESCAN 700 in retina surgery

Monitor vitreous traction during macula surgery.

ZEISS RESCAN 700 in cornea surgery

Check the position of the craft and assess the interface to the patient cornea in DSEAK.

Product video

Videoplayer-Startimage
Sorry, this shouldn't have happened:
Video player failed to load.

See more in retina surgery

When performing a retina procedure, there are times when a little more information would be helpful for better management of procedures. That’s where the OPMI LUMERA 700® from ZEISS comes in.

Fundus viewing system

See more in cataract surgery

For cataract surgery, SCI and CALLISTO eye® from ZEISS provide the best anterior visualization and highly precise* assistance functions to accelerate procedural workflow and improve surgical accuracy.

Assistance functions in the eyepiece

Integrated Video Solutions

The integrated video solutions for surgical microscopes are the most convenient way to generate images for information, documentation, teaching and presentation purposes. Due to the built-in camera systems with factory aligned optics the video solution works well out of the box. Enjoy the beauty and ergonomic advantages of the surgical microscope without any impairment by cables or bulky video adapters. The integrated control allows management of the video solution together with the surgical microscope, which means that it is streamlined with the surgical workflow.

LUMERA 700 HD Video Solution

HD Video Solution

  • Perfectly focused and sharp pictures with the fully integrated 3 Chip HD Camera (1080p). A high definition video camera with high sensitivity especially designed for different light conditions in anterior and posterior segment.
  • Always optimized video image for ophthalmic surgery since the settings are aligned to your workflow and the microscope settings. For example, automatic change between anterior and posterior segment surgery.

doctor in scrubs using LUMERA 700 Recording USB

Integrated HD Recorder

  • The integrated HD Recorder (1080p) can be operated by the foot control panel or handgrip of the microscope head.
  • Patient names can be easily assigned to video data.
  • The videos and still images are transferred directly to a USB storage media or to a shared directory in the Local Area Network (LAN Storage).

LUMERA 700 Monitor 400

Integrated 22" HD Monitor

  • To support the OR staff with surgical microscope images, the integrated 22'' HD monitor has a wide viewing angle and can be positioned very flexibly. The OR team can observe the procedure in sharp and colorful images.
  • The images of the integrated video solution can be connected to secondary monitors or other video systems in the OR using standard video interfaces.
  • The built-in HD video camera is aligned with the CALLISTO eye enabling valuable assistance functions.

External Video Components

To support all requirements or wishes for customized video solutions, external components can be mounted to the surgical microscope system. The external attachment via standard optical and mechanical interfaces increases the flexibility and retrofitability of the surgical microscopes.

HD Video Monitors

HD Video Monitors

Medical grade HD video monitors (1080p) are available in different sizes that match the surgical microscope video solutions.

LUMERA 700 Ceiling Mount

Ceiling Mount

Spans large distances and features a smooth, motorized lift function that makes it possible to quickly switch between the working and park position. This means you have a lot of headroom, both in the working position and the extremely compact park position.

LUMERA 700 Overhead Display

RESIGHT 700 for retina surgery

OPMI Lumera® 700 and RESIGHT® 700 fundus viewing systems allow you – the retinal surgeon – to clearly recognize every detail of the retina. And as these products work together seamlessly, they offer unparalleled convenience in the OR.

RESIGHT 700

LUMERA 700 Invertertube E

Invertertube E

This facilitates an upright, ergonomic posture, stress-free work and rapid changeover from cataract to case surgery and vice versa. Both, an electrical and a manual version are available.

RESIGHT 700 wireless foot control panel

Wireless foot control panel

It’s time to give you and your team more free space in the OR. Experience the new dimension of freedom with no annoying cables and free positioning in your OR. The ergonomically designed foot control panel (FCP and FCP WL) allows you to control your surgical microscope – intuitively and reliably. You can configure the buttons according to your personal requirements. Additionally to our wireless version, we also offer a wired foot control panel.

LUMERA 700 slit illuminator

Integrated slit illuminator

For slit widths and slit direction of left or right. It simplifies membrane peeling and vitrectomy using a contact glass, without the issue of fitting extra accessories.

LUMERA 700 Keratoscope

Integrated keratoscope

Visualize corneal curvature without interrupting the surgery to adjust equipment.

LUMERA 700 Overhead Display

Overhead display

Shows you the current surgical microscope settings at a glance.

ZEISS OPMI LUMERA 700

Surgical microscope Motorized zoom system with apochromatic lens, zoom ratio 1 : 6
Magnification factor = 0.4 x–2.4 x
Focusing: electric / motorized, focus range: 70 mm
Objective lens: f = 200 mm (optionally also f = 175 mm or f = 225 mm with support ring)
Binocular tube: Invertertube E (optionally also Invertertube, 180° swivel tube,
f = 170 mm, inclined tube, f = 170 mm)
Wide-angle eyepiece 10 x (optionally also 12.5 x)
Light source
SCI: Coaxial and full-field illumination (patent pending)

Fiber-optic illumination Superlux® Eye:

  • Xenon short arc reflector lamp with HaMode filter
  • Backup lamp in lamp housing, can be slid into position manually

LED fiber optic light source:

  • Near-daylight color temperature
  • 50,000 hour lifetime
  • HaMode filter
  • 25 % gray filter

For all light sources:

  • Blue blocking filter
  • Optional: Fluorescence filter
Slit lamp Slit widths: 0.2 mm, 2 mm, 3 mm, 4 mm
Slit height: 12 mm
XY coupling Travel range: max. 61 mm x 61 mm
Automatic centering at the touch of a button
Video monitor 22” LCD display
Resolution: 1,680 x 1,050
Stand Maximum permissible weight load of the spring arm:
When the surgical microscope is attached to the arm (without tube, eyepiece or objective lens) and the X Y coupling is also attached, a maximum of 9 kg of additional accessories can be attached to the spring arm

ZEISS RESCAN 700

OCT engine
SD OCT (spectral domain)
Wavelength 840 nm
Scanning speed 27.000 A-scans per second
Scan parameters
A-scan depth: 2.0 mm in tissue
Axial resolution: 5.5 μm in tissue
Scan length adjustable 3–16 mm
Scan rotation adjustable 360°
Scan modes for live and capture acquisition

Live:

  • 1-line
  • 5-lines
  • cross hair
Capture:
  • 1-line
  • 5-lines
  • cube

RESIGHT Family

Mechanical data Focus range with LH175 lens holder: 31 mm (position of intermediate image)
Focus range with LH200 lens holder: 38 mm (position of intermediate image)
Rotation angle of lens revolver and holder: 0°–360°
Lenses included 60 D, 128 D
Weight ZEISS RESIGHT 500 (manual): 0.45 kg
ZEISS RESIGHT 700 (motorized): 0.50 kg

ZEISS CALLISTO eye

Touch screen Projected Capacitive Touch (PCT) with externed transparency, scratch-proof
Processor Intel® Core i7 620M 2.66 GHz
Hard drive SATA, 500 GB
Display Integrated 22” color flat screen with high luminosity and wide viewing angle
Video signals PAL 576i50; NTSC 480i60; 1080i50; 1080i60
Full functionality and usability in conjunction with ZEISS CALLISTO eye is only possible with camera models from Carl Zeiss Meditec AG
Ports 1 × CAN-Bus, 1 × RS232, 2 × 1 Gigabit Ethernet, 5 × USB2.0, 1 × potential equalization
Video input 1 × Y/C, 1 × HD-SDI
Video output 1 × VGA, 2 × HDMI
Connectivity Integrated RJ45 10 / 100Base-T Ethernet port for connection to ZEISS OPMI LUMERA 700 and hospital network
Weight 15 kg

Optime visible service quality

OPTIME

Visible service quality

From preventive maintenance to spare part coverage, OPTIME encompasses the full range of service offerings to ensure maximum system availability and workflow convenience. Benefit from optimum service support over the entire life cycle of your equipment. Additionally, with predictable service expenses, OPTIME makes it easy for you to improve business planning and forecasting. With an experienced and trusted partner at hand.  

Please click here, to learn more about our comprehensive service agreements OPTIME prevent, OPTIME advanced and OPTIME complete.

OPMI Lumera 700

A unique microscope for cataract and retina surgery

Page(s): 18
Filesize: 2,144 kB
Revision