Reliable monofocal hydrophobic IOL performance

ZEISS 3-piece IOLs are available in a spheric (CT LUCIA 202) and an aspheric (CT LUCIA 602)* version. Both featuring highly stable PVDF haptics, designed to ensure IOL stability in the capsular bag. CT LUCIA® 3-piece IOLs from ZEISS are glistening-free1,2 and have a 360° square edge design for a low PCO rate3.

*Available in the US only

High corrected visual acuity

Good refractive results

Low inflammatory reaction

Designed to ensure IOL stability in the capsular bag

ZEISS 3-piece IOLs are designed for cases when IOL stability in the capsular bag is challenging. Providing consistently high corrected visual acuity1, achieving good and precise refractive results2, ensuring low rate of early post-operative Nd:YAG capsulotomies2 and enabling low inflammatory reaction.1

ZEISS 3-piece IOLs
ZEISS 3-piece IOLs
ZEISS CT LUCIA 202

ZEISS CT LUCIA 202

  • Monofocal, spherical
  • PVDF haptics designed for better capsular bag stability and to eliminate capsular bag stretching
  • 360° square-edge design to reduce PCO
ZEISS CT LUCIA 602

ZEISS CT LUCIA 602

  • Monofocal, aspheric
  • PVDF haptics designed for better capsular bag stability and to eliminate capsular bag stretching
  • 360° square-edge design to reduce PCO
  • Featuring the patented ZO Asphericity Concept (ZO: ZEISS Optic)4 designed to compensate for a range of aberrations, providing better image quality in real-life conditions
  • Available in the US only

High corrected visual acuity1

The high stability of the lens in the capsular bag together with its good positioning behaviour supporting good visual outcome after surgery.

Good refractive results2

The reliable performance of the lens after surgery when it comes to IOL stability in the capsular bag as well as low amount of post-surgery complications ensuring good refractive results of the lens.

Low inflammatory reaction1

The safety of the lens after implantation proved to be very re-ensuring with low rates of post- surgery events. Inflammatory reaction were minimal and mostly related to the procedure itself and not to the IOL.

Downloads

ZEISS CT LUCIA 202 Technical Specifications

ZEISS CT LUCIA 202
Technical Specifications

page(s): 2
file size: 92 kB

CT LUCIA 602 ZEISS 3-piece IOL (Formerly EC-3 PAL) Technical Specifications

CT LUCIA 602
ZEISS 3-piece IOL (Formerly EC-3 PAL)
Technical Specifications
page(s): 4
file size: 935 kB

CT LUCIA 202 Handling instruction

CT LUCIA 202
Handling instruction

page(s): 2
file size: 374 kB

ZEISS CT LUCIA 602 (Formerly EC-3 PAL) and Z Cartridge IOL Delivery System Handling instructions

ZEISS CT LUCIA 602 (Formerly EC-3 PAL) and Z Cartridge IOL Delivery System
Handling instructions
page(s): 2
file size: 2000 kB

ZEISS CT LUCIA 202

ZEISS CT LUCIA 602

Specification Comparison

ZEISS CT LUCIA IOL 3-piece family

Features CT LUCIA® 202 CT LUCIA® 602

Optic Design

Monofocal, spheric

Monofocal, aspheric

Material

Hydrophobic acrylic

Hydrophobic acrylic with Polyvinylidene fluoride (PVDF) monofilament haptics

Optic Diameter

6.0 mm

6.0 mm

Total Diameter

13.0 mm

13.0 mm

Haptic Angulation

Lens Design

Three-piece

Three-piece

Incision Size

2.8 mm

2.8 mm

Company Labeled A-Constant5

118.2

117.7

Diopter Range

From +4.0 to +34.0 D, 0.5 D increments

From +4.0 to +34.0 D, 0.5 D increments

ACD6

5.1

4.8

Abbe

50

50

Implantation in

Capsular bag

Bag

Injector / Cartridge Set6

DUALTEC™ OD655 Injectorfor diopter range +4.0 to +34.0 D

ZEISS R28 IOL Delivery System with ZEISS Z28 Cartridge IOL Delivery System for diopter range +4.0 to +34.0 D

Available services

Online shop

ZEISS products at your fingertips

Digital service hub

Less administrative efforts, more time for essential tasks

Lens constants

Optimized for IOL calculation

Vision simulation tool

A schematic presentation of visual perception

Make a sales request

Any questions about buying our products?

Talk to customer care

Do you need assistance or have general questions about your product?

Stay up to date

Subscribe to our newsletter and never miss important updates

  • 1 EC-3 Pivotal Clinical Study (FDA IDE study) , n=324, 12 month.
  • 2 European EC-3 Clinical Investigation, n=96, 6 month, South American EC-3 Clinical Investigation.
  • 3 Borkenstein & Borkenstein (2018) Clinical Ophthalmology 2018:12 1219–1227.
  • 4 Designed to compensate for a range of aberrations, arising from different corneal shapes and lens misalignments. As a result, it provides better imaging quality for real-life conditions.
  • 5 For optimized A Constants and ACD Constants refer to IOLCon: www.iolcon.org
  • 6 Please refer to our web page for the most up-to-date references: www.zeiss.com/injectors