ZEISS CT LUCIA Family
Product Family

ZEISS CT LUCIA Family

Treating a wide range of patients with a unique ZEISS Optic.

The CT LUCIA® 621P/PY – a new generation of aspheric IOL, applied on a monofocal hydrophobic C-loop platform. The patented asphericity concept of the ZEISS CT LUCIA is designed to mitigate against potential decentration issues and to confidently deliver good visual outcomes.

The architecture of the IOL enables very stable positioning in the capsular bag for consistent and excellent performance. The latest CT LUCIA 621P/PY comes in a new and improved fully preloaded injector system for an easy and intuitive cataract workflow.

Consistent visual outcomes¹

Excellent stability

Intuitive injector handling

ZEISS CT LUCIA 621P

Aspheric C-loop

ZEISS CT LUCIA 621P

  • Monofocal
  • Aspheric (aberration-correcting)
  • Hydrophobic acrylic with heparin-coated2 surface
ZEISS CT LUCIA 621PY

Aspheric C-loop

ZEISS CT LUCIA 621PY

  • Monofocal
  • Aspheric (aberration-correcting)
  • Hydrophobic acrylic with heparin-coated2 surface
  • Blue light filter
ZEISS CT LUCIA 221P

Spherical C-loop

ZEISS CT LUCIA 221P

  • Monofocal
  • Spheric
  • Hydrophobic acrylic with heparin-coated2 surface
Simulated predicted visual acuity under decentration
ZEISS CT LUCIA family Forgiving to decentration
Fig. 1. Influence of decentration on predicted mesopic visual acuity.

Consistent visual outcomes1

The sophisticated and patented ZEISS Optic (ZO) Asphericity Concept of the ZEISS CT LUCIA 621P/PY is designed to compensate for a wide range of aberrations resulting from different corneal shapes and lens positions. With its uniquely forgiving design it delivers good visual outcomes for a broad range of patients and surgical situations.

Excellent stability

ZEISS CT LUCIA 621P/PY IOLs feature an optic-haptic junction designed for refractive stability. Coupled with step-vaulted C-loop haptics, this enables centering while maximizing direct capsular contact, thus ensuring stability and supporting a consistent, stable axial IOL position in the capsular bag.

Intuitive injector handling

The design of the latest fully preloaded injection system of the ZEISS CT LUCIA has been improved to make handling easier and intuitive for the target users. Recent enhancements simplify the surgical workflow, providing a smooth preparation process that enables successful implantation of the lens in an easy and efficient manner. 

ZEISS CT LUCIA family Intuitive injector handling

Are you a patient?

Please visit our patient website for more information on cataract treatment:

Maximize your product usage with MyZEISS

  • Get latest training content and clinical insights from peers
  • Benefit from patient support materials
  • Access tools and manage devices online

Downloads

ZEISS CT LUCIA

ZEISS CT LUCIA
Treating a wide range of patients with a unique ZEISS Optic
page(s): 18
file size: 76.6 MB

CT LUCIA 211P Technical Specifications

CT LUCIA 201P
Technical Specifications
page(s): 1
file size: 51 kB

CT LUCIA 211P Technical Specifications

CT LUCIA 211P
Technical specifications
page(s): 2
file size: 98 kB

CT LUCIA 221P Technical Specifications

CT LUCIA 221P
Technical Specifications
page(s): 2
file size: 108 kB  

CT LUCIA 611P CT LUCIA 611PY Technical Specifications

CT LUCIA 611P
CT LUCIA 611PY
Technical specifications
page(s): 2
file size: 107 kB

CT LUCIA 621P
CT LUCIA 621PY

Technical Specifications
page(s): 2
file size: 116 kB 

CT LUCIA 601P
CT LUCIA 601PY

Technical Specifications
page(s): 2
file size: 160 kB 

CT LUCIA 211P/611P/611PY Handling instructions

CT LUCIA 211P/611P/611PY
Handling instructions
page(s): 2
file size: 241 kB

CT LUCIA 221P/621P/621PY Handling instructions

CT LUCIA 221P/621P/621PY
Handling instructions
page(s): 2
file size: 325 kB

CT LUCIA 211P/611P/611PY
Handling instruction video

CT LUCIA 221P/621P/621P
Handling instruction video

Unable to load form (multistep).

Specification Comparison

ZEISS CT LUCIA family

Features CT LUCIA 211P
CT LUCIA 221P (coming soon)

Optic Design

Monofocal, spheric

Monofocal, spheric

Material

Hydrophobic acrylic with heparin-coated2 surface

Hydrophobic acrylic with heparin-coated2 surface

Optic Diameter

6.0 mm

6.0 mm

Total Diameter

13.0 mm

13.0 mm

Haptic

Step vaulted

Step vaulted

Lens Design

Single-piece

Single-piece

Incision Size

2.2 – 2.6 mm (depending on diopter)

2.2 – 2.4 mm (depending on diopter)

Company Labeled A-Constant8

119.8

119.8

Diopter Range

From +4.0 to +34.0 D, 0.5 D increments

From +0.0 to +30.0 D, 0.5 D increments

Abbe Number

51

51

ACD8

6.03

6.03

Refractive Index

1.49

1.49

Implantation in

Capsular bag

Capsular bag

Injector / Cartridge Set

BLUEJECT 2.0 Injectorfor diopter range +4.0 to +24.0 D

BLUEJECT 2.2 Injectorfor diopter range +24.5 to +30.0 D

BLUEJECT 2.4 Injectorfor diopter range +30.5 to +34.0 D

BLUESERT 2.2 Injector for diopter range +0.0 to +24.0

BLUESERT 2.4 Injector for diopter range +24.5 to +30.0

 

Features CT LUCIA 611P   CT LUCIA 611PY  

Optic Design

Monofocal, aspheric (aberration correcting)

Monofocal, aspheric (aberration correcting)

Material

Hydrophobic acrylic with heparin-coated2 surface

Hydrophobic acrylic with heparin-coated2 surface and blue light filter

Optic Diameter

6.0 mm

6.0 mm

Total Diameter

13.0 mm

13.0 mm

Haptic

Step vaulted

Step vaulted

Lens Design

Single-piece

Single-piece

Incision Size

2.2 – 2.6 mm (depending on diopter)

2.2 – 2.6 mm (depending on diopter)

Company Labeled A-Constant8

119.9

119.9

Diopter Range

From +4.0 to +34.0 D, 0.5 D increments

From +4.0 to +34.0 D, 0.5 D increments

Abbe Number

51

50

ACD8

6.14

6.14

Refractive index

1.49

1.49

Implantation in

Capsular bag

Capsular bag

Injector / Cartridge Set

BLUEJECT™ 2.0 Injectorfor
diopter range +4.0 to +24.0 D

BLUEJECT 2.2 Injectorfor
diopter range +24.5 to +30.0 D

BLUEJECT 2.4 Injectorfor
diopter range +30.5 to +34.0 D

BLUEJECT 2.0 Injectorfor diopter range +4.0 to +24.0 D

BLUEJECT 2.2 Injectorfor diopter range +24.5 to +30.0 D

BLUEJECT 2.4 Injectorfor diopter range +30.5 to +34.0 D

Features CT LUCIA 621P  
CT LUCIA 621PY  

Optic Design

Monofocal, aspheric (aberration-correcting)

Monofocal, aspheric (aberration-correcting)

Material

Hydrophobic acrylic with heparin-coated2 surface

Hydrophobic acrylic with heparin-coated2 surface and blue light filter

Optic Diameter

6.0 mm

6.0 mm

Total Diameter

13.0 mm

13.0 mm

Haptic

Step vaulted

Step vaulted

Lens Design

Single-piece

Single-piece

Incision Size

2.2 – 2.6 mm (depending on diopter)

2.2 – 2.6 mm (depending on diopter)

Company Labeled A-Constant8

120.2

120.2

Diopter Range

From +0.0 to +34.0 D, 0.5 D increments

From +0.0 to +34.0 D, 0.5 D increments

Abbe Number

51

50

ACD8

6.29

6.29

Refractive index

1.49

1.49

Implantation in

Capsular bag

Capsular bag

Injector / Cartridge Set

BLUESERT™ 2.2 Injector for diopter range +0.0 to +24.0

BLUESERT 2.4 Injector for diopter range +24.5 to +30.0

BLUESERT 2.6 Injector for diopter range +30.5 to +34.0

BLUESERT 2.2 Injector for diopter range +0.0 to +24.0

BLUESERT 2.4 Injector for diopter range +24.5 to +30.0

BLUESERT 2.6 Injector for diopter range +30.5 to +34.0

Available services

Online shop

ZEISS products at your fingertips

Digital service hub

Less administrative efforts, more time for essential tasks

Lens constants

Optimized for IOL calculation

Vision simulation tool

A schematic presentation of visual perception

Make a sales request

Any questions about buying our products?

Click here

to get direct assistance from our service team.

Stay up to date

Sign up for updates on current topics, news and events.

  • 1 The data is taken from a simulation. The transferability of the results of such a simulation to patients with an actual implanted intraocular lenses has not yet been scientifically proven. Whether the simulated impressions correspond to the actual visual impressions must be clarified in future invasive studies.
  • 2 Fragment of heparin used in IOL surface coating with no pharmacological, immunological or metabolic action.
  • 3 Based on physiologically weighted MTF-area (subject to clinical verification)
  • 4 For spherical aberration (SA) only
  • 5 Internal report on CT LUCIA 621P data collection (Dr Cuttita) - Version 1.1 dated 19.11.2019.
  • 6 CT LUCIA 621P - Surgeon evaluation report (Apr-Sep 2019) - Report on surgery Performance CT LUCIA 621P injector.
  • 7 Results are based on 521 implantations.
  • 8 For optimized A Constants and ACD Constants refer to IOLCon: www.iolcon.org