IOLMaster moment
reliabilityMADE BY ZEISS
Trusting the experience of
100 million IOL power calculations.
ZEISS IOLMaster 500
reliabilityMADE BY ZEISS
Unique distance-independent keratometry

ZEISS IOLMaster 500

Unique distance-independent keratometry

Learn more

IOLMaster-moment
Trust the experience of 100 million IOL power calculations. ZEISS IOLMaster 500

Schedule your Consultation

IOLMaster 500 from ZEISS

Defining biometry

  • Highlights

    The ZEISS IOLMaster® 500 is the gold standard in optical biometry with more than 100 million successful IOL power calculations to date. With the ZEISS IOLMaster 500 you get a piece of cutting-edge technology that points the way to the future of optical biometry.

    Unique ULIB data set

    Improving refractive outcomes

    Any intraocular lens calculation is only as reliable as the lens constant it is based on. More than 50,000 sets of patient data created with the ZEISS IOLMaster are the basis of more than 270 optimized lens constants in the User Group for Laser Interference Biometry (ULIB) website–—absolutely unique in the industry.1 Together with its one-of-a-kind distance independent telecentric keratometry and the integrated Holladay 2 formula, the gold standard in optical biometry helps you improve your refractive outcomes.2

    Advanced measurement of challenging eyes

    Advanced measurement of challenging eyes

    The true test of a biometer is its performance with challenging eyes. In denser cataracts the ZEISS IOLMaster 500 achieves a measurement success ratio that is up to 20% higher than that of other optical biometry devices.3 Even with staphyloma, pseudophakic and silicone-filled eyes the ZEISS IOLMaster 500 measures along the visual axis, yielding the relevant axial distance. And with its Haigis-L formula on board the ZEISS IOLMaster 500 is dedicated to myopic and hyperopic post-LVC cases.

    Proven toric outcomes, IOLMaster 500

    Proven toric outcomes

    The results of a meta-analysis of 28 published clinical papers covering more than 1900 cases show that the reported clinical outcomes for the ZEISS IOLMaster with regard to residual astigmatism “[...] exceed, or are at least as good as those using manual or automated keratometry.”4

    Markerless toric IOL alignment

    Markerless toric IOL alignment

    The Reference Image is the starting point of a markerless toric IOL workflow: an image of the eye is taken along with the keratometry measurement. Both, reference images and keratometry data are transferred to the ZEISS CALLISTO eye® computer-assisted surgery system. Finally, all data needed for precise5 and markerless toric IOL alignment is injected into the eyepiece of the surgical microscope from ZEISS.

    Ease of use

    Ease of use

    A well-designed user interface, plausibility checks, distance-independent measurements and an up to 4 times faster reading compared to other optical devices lead to a one-of-a-kind usability and reduced chairtime.6 A difference you, your team and your patients will notice every day.

    Cataract Community

    Cataract Community

    Get quick and easy access to clinical cases, videos and more regarding the ZEISS IOLMaster 500. Discover the latest findings in optical biometry, share your opinion and discuss with peers.

    Join the Cataract Community
  • Technical Data
    Technical data IOLMaster 500 from ZEISS
    Measurement range Axial length 14 – 38 mm
    Corneal radii 5 – 10 mm
    Anterior chamber depth 1.5 – 6.5 mm
    White-to-white 8 –16 mm
    Display scaling Axial length 0.01 mm
    Corneal radii 0.01 mm
    Anterior chamber depth 0.01 mm
    White-to-white 0.1 mm
    IOL calculation formulas Holladay 1 and 2, Hoffer® Q, Haigis, SRK® II, SRK® / T
    Clinical history and contact lens fitting method for calculation of corneal refractive power following refractive corneal surgery
    Haigis-L IOL calculation for eyes following myopic / hyperopic LASIK / PRK / LASEK surgery
    Calculation of phakic anterior and posterior chamber implants
    Optimization of IOL constants
    Interfaces Ultrasound data link
    ZEISS eyecare data management system FORUM®
    ZEISS computer-assisted surgery system CALLISTO eye (via USB)
    Data interface for electronic medical record (EMR) / patient management systems (PMS)
    Data export to USB storage media
    Export database for Holladay IOL Consultant and HIC.SOAP Pro
    Ethernet port for network connection and network printer
    Line voltage 100 – 240 V ± 10 % (self sensing)
    Line frequency 50 – 60 Hz
    Performance consumption max. 75 VA
    Laser class 1


    DICOM Conformance Statements

    DICOM Conformance Statements

    A list of DICOM 3.0 Conformance Statements for products from Carl Zeiss Meditec.

    Find DICOM Conformance Statements here
  • Options & Accessories
    Reference Image

    Reference Image

    For markerless toric IOL alignment

    The Reference Image supports a markerless toric IOL workflow. It references the patient’s astigmatic axis relative to his/her eye ball position using small blood vessels on the eye as landmarks. Reference image and keratometry data are transferred to the ZEISS CALLISTO eye® computer-assisted cataract surgery system. Finally, all data needed for precise5 and markerless toric IOL alignment is injected in color and high resolution into the eyepiece of the surgical microscope from ZEISS.        

  • Showroom

    Experience the IOLMaster 500

    See why the IOLMaster 500 defines biometry. Test it yourself!

     

     

  • Services

    OPTIME from ZEISS

    Support whenever you need it

    Do you rely on high system availability? If your answer is yes, then why not consider our ZEISS OPTIME service agreements, which are designed to ensure the readiness of your medical equipment at all times.

    More about ZEISS OPTIME

    REMOTE Service from ZEISS

    Expert assistance from afar

    Do you need immediate service support? ZEISS Remote Service offers online support for customers with ZEISS OPTIME advanced and ZEISS OPTIME complete agreements.

    More about ZEISS Remote Service

    Financial Solutions from ZEISS

    The smart way to acquire ZEISS technology

    Want the latest technology from ZEISS despite a tight budget? ZEISS Financial Solutions might have the right financing options for you.

    More about ZEISS Financial Solutions

    Benefit from our customer care packages

    Register for a Service Contract
  • Downloads

    IOLMaster 500 from ZEISS

    Defining biometry

    Page(s): 12
    Filesize: 525 kB

    IOLMaster 500 - Whitepaper

    The IOLMaster and determining toric IOL Power

    Page(s): 6
    Filesize: 75 kB

    IOLMaster 500 - Paper

    IOLMaster and Integration of the Holladay 2 Formula for IOL Calculations

    Page(s): 2
    Filesize: 383 kB

    IOLMaster 500 - Study Overview

    Head-to-Head Comparative Study of Two Optical Biometric Devices in Modern Cataract Surgery

    Page(s): 4
    Filesize: 836 kB

    IOLMaster 500 - Study Overview

    IOLMaster 500 and the Haigis-L Formula in IOL Calculations for Post-Refractive Patients

    Page(s): 2
    Filesize: 650 kB

    Cataract Community

    Cataract Community

    Get quick and easy access to clinical cases, videos and more regarding the ZEISS IOLMaster 500. Discover the latest findings in optical biometry, share your opinion and discuss with peers.

    Join the Cataract Community

Discover more

Sales Request

Any questions about buying our products?

Contact us now

Price Request

Our Sales Team will contact you shortly.

Request a Quote

Schedule your Consultation

Our experts will contact you shortly.

Schedule an Appointment

Customer Care

Need assistance with your product?

Contact us now

Related Products

  • 1 Haigis W, http://www.augenklinik.uni-wuerzburg.de/ulib/
  • 2 Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL, Intraocular lens formula constant optimization and partial coherence interferometry biometry: Refractive outcomes in 8108 eyes after cataract surgery, J Cataract Refract Surg. 2011 Jan;37(1):50-62
  • 3 Rivero L, IOLMaster Version 5 vs. Lenstar LS900, presented at 2010 AAO – MEACO Joint Meeting in Chicago, Illinois.
  • 4 Bullimore MA, MCOptom, PhD, FAAO, The IOLMaster and determining toric IOL Power, white paper
  • 5 Clinical data of Prof. Findl / Dr. Hirnschall presented at ESCRS 2013 – technically verified pre- / intraoperative matching precision ± 1.0° in mean
  • 6 Chen YA, Hirnschall N, Findl O, Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer, J Cataract Refract Surg. 2011 Mar;37(3):513-517