IOLMaster 700 Moment New: with Barrett Suite
Getting fewer refractive surprises. ZEISS IOLMaster 700
IOLMaster 700

ZEISS IOLMaster 700

>99% cataract penetration rate5

More information

IOLMaster 700 New: with Barrett Suite
Get fewer refractive surprises. ZEISS IOLMaster 700

Schedule your Consultation

IOLMaster 700

Next generation biometry from ZEISS

  • Highlights

    With SWEPT Source Biometry and Barrett Suite

    SWEPT Source OCT technology and the Barrett Suite: a powerful combination for fewer refractive surprises. The IOLMaster® 700 from ZEISS with SWEPT Source Biometry® now fully integrates the latest Barrett formulas into one suite. Barrett Universal II, Barrett True-K and Barrett Toric – formulas which also incorporate the influence of the posterior corneal surface.11,12,13

    Loading the player...

    Get fewer refractive surprises

    Tilted lens

    Detect unusual eye geometries
    The ZEISS IOLMaster 700 provides a full-length OCT image showing anatomical details on a longitudinal cut through the entire eye. Thus unusual eye geometries, such as a tilt or decentration of the crystalline lens, can be detected. If left undetected, such critical details can lead to an unsatisfactory post-operative visual experience.

    Fixation check

    Detect poor fixation
    The unique Fixation Check provides you with more confidence in optical biometry. Can you see the foveal pit? If so, you can reduce the risk of refractive surprises due to incorrect measurements caused by undetected poor fixation. If not, you can educate your patients to always fixate on target.

    Visually verify your measurement
    All measurement calipers are shown on the full-length OCT image. Now, for the first time in optical biometry, you can visually verify what structure of the eye has been measured. Complex interpretation of A-scans are no longer necessary. Thus, potential sources of errors are eliminated.

    Improve your refractive outcomes

    IOLMaster 700 repeatability

    Outstanding repeatability
    Repeatability is essential for good refractive outcomes. Thanks to its unique SWEPT Source Biometry with 2,000 scans per second, the repeatability of the ZEISS IOLMaster 700 is absolutely outstanding.

    IOLMaster 700 ULIB

    Get the broadest basis of clinical data
    Leverage the complete "User Group of Laser Interference Biometry" (ULIB) database! You will find optimized lens constants for more than 270 IOL models based on the data from over 50,000 cataract surgeries specifically collected for the IOLMaster. This will help you to improve your refractive outcomes.2

    700 telecentric keratometry

    Unique telecentric keratometry

    ZEISS is the only company that offers an optical biometer with telecentric, and thus distance-independent, keratometry. Its smart optical configuration allows robust and repeatable measurements – especially with restless patients – for superior keratometry measurements.

    Complete set of biometric parameters for latest IOL
    power calculation formulas

    The ZEISS IOLMaster 700 measures all biometric parameters for the latest IOL power calculation formulas

    Show more
    Less

     

    Optimize your workflow

    Case with very dense cataract that could be measured successfully with the ZEISS IOLMaster 700; image courtesy of Prof. M. de La Torre, DLT Ophthalmic Center, Peru

    >99% cataract penetration rate
    Thanks to its unique SWEPT Source Biometry, the cataract penetration of the ZEISS IOLMaster 700 outperforms that of A-scan optical biometry. A comparative clinical study with more than 1200 eyes showed that the
    ZEISS IOLMaster 700 achieves a cataract penetration rate of more than 99%. As a result, the number of ultrasound cases may be reduced by 92%5 saving you valuable time and lowering the risk of refractive surprises caused by imprecise ultrasound measurements.

    Macular hole: Fixation Check image (middle) combined with ZEISS CIRRUS retina OCT image (via photo editor program); Image courtesy of Prof. W. Sekundo, Philipps University Hospital Marburg, Germany

    Get indications for macular pathologies
    The Fixation Check can help you to identify macular pathologies such as macular holes, epiretinal membranes, and age-related macular degeneration in your daily routine. As the ZEISS IOLMaster 700 is clearly not intended to be used for diagnostics, findings need to be verified and pathologies diagnosed with a dedicated retina OCT. Nevertheless, in high-volume practices the ability to detect these eyes preoperatively can be invaluable.6,7,8,9
     

    IOLMaster 700 Haigis Suite

    Toric IOL power calculation made easy
    In the new Haigis Suite, the ZEISS IOLMaster 700 provides the first on-board all-in-one solution for toric IOL power calculation. It combines the well established Haigis formula, the Haigis-L formula for post-LVC cases, and the new Haigis-T for toric IOL in one powerful tool. There is no need to key-in data into the IOL vendors’ online toric power calculation tools.

    IOLMaster 700 usability

    Fast and easy to use

    Thanks to its SWEPT Source Biometry, you can measure both eyes in less than 45 seconds10 (watch video). The multi-touch screen and the new graphical user interface allow for gesture control of the device like you are used to from your smartphone or tablet computer. Alignment assistance functions make the results largely independent from the user and therefore easy to delegate.

    IOLMaster 700 ZEISS Cataract Suite markerless

    Implant toric IOLs markerless – ZEISS Cataract Suite markerless

    The ZEISS IOLMaster 700 is part of the ZEISS Cataract Suite markerless. It acquires a reference image in case of astigmatism during routine biometry. The image of the eye is taken along with the keratometry measurement, all with one device. Both reference image and keratometry data are transferred to the CALLISTO eye® computer assisted cataract surgery system from ZEISS. During surgery, the image is used for intra-operative matching with the live eye image. All data needed is injected into the eyepiece of the surgical microscopes of the OPMI LUMERA® family3 from ZEISS. 

    Show more
    Less
    Cataract Community

    Cataract Community

    Get quick and easy access to clinical cases, videos and more regarding the ZEISS IOLMaster 700. Discover the latest findings in optical biometry, share your opinion and discuss with peers.

    Join the Cataract Community
  • Technical Data
    Technical data IOLMaster 700 from ZEISS
    Measurement range
    Axial length 14 – 38 mm
      Corneal radii 5 – 11 mm
      Anterior chamber depth 0.7 – 8 mm
      Lens thickness 1 – 10 mm (phakic eye)
                           0.13 – 2.5 mm (pseudophakic eye)
      Central corneal thickness 0.2 – 1.2 mm
      White-to-white 8 – 16 mm
    Display scaling
    Axial length 0.01 mm
      Corneal radii 0.01 mm
      Anterior chamber depth 0.01 mm
      Lens thickness 0.01 mm
      Central corneal thickness 1 μm
      White-to-white 0.1 mm
    SD of repeatability4
    Axial length 9 μm
      Corneal radii 0.07 D
      Cylinder > 0.75 D axis 4.5°
      Anterior chamber depth 10 μm
      Lens thickness 19 μm
      Central corneal thickness 2 μm
    IOL calculation formulas
    Barrett Suite* (includes Barrett Toric, Barrett True-K & Barrett Universal II), Haigis Suite [includes Haigis, Haigis-L (for eyes following myopic/hyperopic LASIK/PRK/LASEK, Haigis-T (for toric IOL power)], Hoffer® Q, Holladay 1 & 2, SRK®/T.
    Interfaces
    ZEISS FORUM® eye care data management system
      ZEISS computer-assisted cataract surgery system CALLISTO eye (via USB & FORUM)
      Data interface for electronic medical record (EMR) / patient management systems (PMS)
      Data export to USB storage media
      Ethernet port for network connection and network printer
    Line voltage
    100 – 240 V ± 10 % (self sensing)
    Line frequency
    50 – 60 Hz
    Power consumption
    max. 150 VA
    Laser class
    1

    *optional

    DICOM Conformance Statements

    DICOM Conformance Statements

    A list of DICOM 3.0 Conformance Statements for products from Carl Zeiss Meditec.

    Find DICOM Conformance Statements here
  • Options & Accessories
    IOLMaster 700 Reference Image

    Reference Image

    For markerless toric IOL alignment

    The Reference Image allows a markerless toric IOL workflow. It references the patient’s astigmatic axis relative to his/her eye ball position using small blood vessels on the eye as landmarks. At the same time keratometry measurement is performed and displayed on the ZEISS IOLMaster 700. Both reference image and keratometry data are transferred to the ZEISS CALLISTO eye® computer-assisted cataract surgery system. All data needed is injected into the eyepiece of the surgical microscopes of the OPMI LUMERA® family from ZEISS.

    IOLMaster 700 Barrett Formulas

    Barrett Suite

    Profit from the latest Barrett formulas fully integrated into one suite: Barrett Universal II, Barrett True-K and Barrett Toric – formulas which also incorporate the influence of the posterior corneal surface.

  • Services

    OPTIME from ZEISS

    Support whenever you need it

    Do you rely on high system availability? If your answer is yes, then why not consider our ZEISS OPTIME service agreements, which are designed to ensure the readiness of your medical equipment at all times.

    More about ZEISS OPTIME

    REMOTE Service from ZEISS

    Expert assistance from afar

    Do you need immediate service support? ZEISS Remote Service offers online support for customers with ZEISS OPTIME advanced and ZEISS OPTIME complete agreements.

    More about ZEISS Remote Service

    Financial Solutions from ZEISS

    The smart way to acquire ZEISS technology

    Want the latest technology from ZEISS despite a tight budget? ZEISS Financial Solutions might have the right financing options for you.

    More about ZEISS Financial Solutions

    Benefit from our customer care packages

    Register for a Service Contract
  • Downloads

    Articles, White Papers, Brochures

    Find out more about first hands-on experiences and cases of your peers using the ZEISS IOLMaster 700 in their day-to-day practice, as well as about current results of clinical studies. You can also download the latest version of the brochure to read at your leisure.

    Brochure: ZEISS IOLMaster 700

    Getting fewer refractive surprises

    Page(s): 12
    Filesize: 4,983 kB

    Case Study: Fixation Check

    Author: Prof. Sabong Srivannaboon
    Published in: Cataract & Refractive Surgery Today Europe

    Page(s): 1
    Filesize: 1,378 kB

    Case Study: IOLMaster 700 in extreme cataract

    Author: Prof. Mario de La Torre
    Published in: Cataract & Refractive Surgery Today

    Page(s): 1
    Filesize: 1,429 kB

    Article: The IOLMaster 700 - New technology provides increased speed, ULIB compatibility, and fewer refractive surprises

    Author: Prof. Walter Sekundo
    Published in: Cataract & Refractive Surgery Today

    Page(s): 2
    Filesize: 165 kB

    Article: IOLMaster 700 - Better Predictability and Optimized Workflow Compared with other Biometers

    Author: Prof. Oliver Findl
    Published in: Cataract & Refractive Surgery Today Europe

    Page(s): 2
    Filesize: 627 kB

    Article: The new IOLMaster 700 from ZEISS — First Results concerning the Cataract Penetration Rate

    Author: Dr. Michael Puech
    Published in: Ophthalmology Times Europe

    Page(s): 2
    Filesize: 5,437 kB

    White Paper: Toric IOL Power Calculation

    Author: Prof. Wolfgang Haigis

    Page(s): 4
    Filesize: 91 kB

    Cataract Community

    Cataract Community

    Get quick and easy access to clinical cases, videos and more regarding the ZEISS IOLMaster 700. Discover the latest findings in optical biometry, share your opinion and discuss with peers.

    Join the Cataract Community

Discover more

Sales Request

Any questions about buying our products?

Contact us now

Price Request

Our Sales Team will contact you shortly.

Request a Quote

Schedule your Consultation

Our experts will contact you shortly.

Schedule an Appointment

Customer Care

Need assistance with your product?

Contact us now

Related Products

  • 1 LENSTAR LS900, HS-Art.No. 1511.7220032.02060, standard deviation (1,σ); IOLMaster 500, Vogel A, Dick B, Krummenauer F:Reproducibility of optical biometry using partial coherence interferometry. Intraobserver and Interobserver reliability. J Cataract Refract Surg 27:1961-1968, 2001 standard deviation (1,σ); IOLMaster 700 see technical data
  • 2 Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL, Intraocular lens formula constant optimization and partial coherence interferometry biometry: Refractive outcomes in 8108 eyes after cataract surgery, J Cataract Refract Surg. 2011 Jan;37(1):50-62
  • 3 ZEISS Cataract Suite markerless is available with: S7 / OPMI Lumera, S88 / OPMI Lumera T, OPMI Lumera i and OPMI Lumera 700
  • 4 Carl Zeiss Meditec AG, clinical trial, EUDAMED No. CIV-12-08-008641
  • 5 R. Varsits, N. Hirnschall, B. Doeller, O. Findl; Increasing the number of successful axial eye length measurements using swept-source optical coherence tomography technology compared to conventional optical biometry; presented at ESCSR 2016
  • 6 Bertelmann et al.; Foveal pit morphology evaluation during optical biometry measurements using a full-eye-length swept-source OCT scan biometer prototype; European Journal of Ophthalmology, Nov/Dec 2015
  • 7 Walter Sekundo, The IOLMaster 700 – New technology provides increased speed, ULIB compatibility, and fewer refractive surprises.; Cataract & Refractive Surgery, Nov/Dec 2015
  • 8 Oliver Findl; CASE STUDY: IOLMaster 700 Indicating Abnormal Macular Morphology, CRS Today March 2016
  • 9 Hirnschall N, Leisser C, Radda S, Maedel S, Findl O. Macular disease detection with a swept source optical coherence tomography based biometry device in patients scheduled for cataract surgery. JCRS accepted 2016.
  • 10 Depending on experience of operator and eye conditions.
  • 11 Kane, J.X., et al., Intraocular lens power formula accuracy: Comparison of 7 formulas. J Cataract Refract Surg, 2016. 42(10): p. 1490-1500
  • 12 Abulafia, A., et al., Prediction of refractive outcomes with toric intraocular lens implantation. J Cataract Refract Surg, 2015. 41(5): p. 936-44.
  • 13 Abulafia, A., et al., Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia. J Cataract Refract Surg, 2016. 42(3): p. 363-9.
We use cookies on this site. Cookies are small text files that are stored on your computer by websites. Cookies are widely used and help to optimize the pages that you view. By using this site, you agree to their use. more