ATLAS 9000 stage

ATLAS 9000

Greater Productivity through Connectivity

Schedule your Consultation

ATLAS 9000 Corneal Topography System

  • Highlights
    woman and doctor with atlas 9000

    ATLAS 9000 Corneal Topography System

    Simply Accurate for Maximum Productivity
    • By merging proven Atlas® Placido disk technology with Visante OCT pachymetry, Visante omni now provides comprehensive anterior and posterior topography

    • Proven Placido Disk Technology with patented Cone-of-Focus™ Alignment System

    • SmartCapture™ Image Analysis Technology analyzes multiple images during alignment and automatically selects the highest quality image

    • MasterFit™ II Contact Lens Software helps streamline the fitting of gas permeable (GP) lenses and guides you through difficult and specialty fits

    • Data compatibility with previous generation ATLAS Corneal Topography Systems to facilitate data management and patient follow up
  • Unique Features
    Atlas 9000 Placido Disk Technology

    Patented Placido Disk Technology

    Placido-disk-drawing-2

    Triangulation with Cone-of-Focus, Placido rings, and corneal surface

    Placido Disk Technology with Cone-of-Focus Alignment System

    Proven, patented technology
    • Patented Cone-of-Focus™ Alignment System and Arc-Step Algorithm deliver sub-micron elevation accuracy
    • Using triangulation, the advanced Atlas Arc-Step algorithm provides reliable surface reconstruction
    • 22-ring Placido disk optimized to avoid ring crossover, which means reliable results for a wide range of patients
    • Long, comfortable 70 mm working distance minimizes focusing error found in “small cone” systems
    two women with atlas 9000

    SmartCapture Image Analysis

    Technology that helps your staff get the right image the first time
    • SmartCapture™ analyzes 15 digital images per second during alignment and automatically selects the highest quality image
    • Next-generation image processing provides more repeatable, reliable results, even in difficult cases
    • Less dependence on operator technique means greater efficiency and fewer repeat exams
    Assess higher-order corneal aberrations and simulate visual acuity

    Assess higher-order corneal aberrations and simulate visual acuity

    Optimize the selection of aspheric IOLs using Zernike corneal wavefront analysis

    Optimize the selection of aspheric IOLs using Zernike corneal wavefront analysis

    Corneal Wavefront Analysis

    A valuable tool for patient education and treatment selection

    Corneal Wavefront Analysis takes corneal topography to a new dimension. Using ray tracing technology, the Atlas displays higher-order corneal aberrations, providing valuable insight for patient education and treatment planning.

    • Educate patients about higher-order aberrations and simulate visual acuity
    • Assess corneal refraction with image simulation and point spread function
    • Measure corneal spherical aberration with Zernike analysis to optimize the selection of aspheric IOLs
    • View the effects of individual higher order corneal aberrations
    • View changes in contrast sensitivity through the modulation transfer function (MTF)
    Scotopic and photopic pupil images

    Scotopic and photopic pupil images

    Automatic Horizontal Visible Iris Diameter (HVID)

    Automatic Horizontal Visible Iris Diameter (HVID) or “white to white” measurement simplifies the selection of contact lenses

    Easily measure and display HVID

    Easily measure and display HVID for both eyes with OD/OS Comparison Display

    Automatic Pupillometry and HVID Measurement

    Tools that enhance contact lens fitting and refractive surgery planning
    • Pupil size, measured at two levels of illumination (scotopic and photopic @700 nm), provides insight into optical zone under varying light conditions.
    • View centration of LASIK or orthokeratology treatment in relation to pupil center to assess treatment effectiveness
    • Improve multifocal contact lenses selection by understanding patient's pupil size at two levels of illumination
    • Streamline contact lens selection and fitting with automatic Horizontal Visible Iris Diameter (HVID) measurement
    Atlas 9000
    woman using altlas9000

    Ergonomic Design

    Ideally suited for you and your patients
    • Compact, integrated system with powerful computer and analysis software
    • Unique chinrest positions patient for easy image capture and wide peripheral coverage and automatically detects OD/OS
    • Non-visible Placido ring illumination is comfortable for even the most light-sensitive patients
    pathfinder II atlas 9000

    PathFinder II Corneal Analysis Software

    Take the art out of topography analysis

    PathFinder II Corneal Analysis Software for the Atlas Corneal Topography System (Model 9000) is a comprehensive, easy to understand, and reliable anterior topographic screening tool to assist with refractive surgery screening and to help identify abnormal corneal conditions for monitoring and follow-up. Using next-generation analysis technology, PathFinder II instantly provides probabilities for 5 different corneal conditions by comparing topography exams to an extensive clinical database.

    PathFinder II summary screen

    PathFinder II summary screen

    1. Comprehensive Clinical Database

    PathFinder II features a statistically significant clinical database established from a multicenter clinical study that characterized 5 different corneal conditions including:

    Normal corneas

    • Suspect/clinical keratoconus
    • Myopic laser vision correction
    • Hyperopic laser vision correction
    • Other non-normal conditions such as corneal transplant
    pathfinder II next generation analysis software

    Mean curvature analysis eliminates corneal astigmatism to reveal underlying corneal irregularities

    2. Sophisticated, Next-Generation Analysis Software

    Overcoming limitations inherent in traditional corneal topography, PathFinder II incorporates novel three-dimensional mean curvature analysis, which has been shown to be very sensitive to detecting corneal shape abnormalities such as keratoconus1. An advanced Support Vector Machine algorthim analyzes multiple parameters from the mean curvature map and compares them to PathFinder II's extensive clinical database.

    3. Results You Can Use

    You can count on PathFinder II to make topography analysis simple and reliable.

    • Validation of PathFinder II with an independent data set demonstrated greater than 90% sensitivity, specificity, and accuracy in detecting normal versus abnormal corneas2.
    • Color-coding of PathFinder II parameters quickly indicates which parameters are beyond normal limits any may contribute to specific classifications.
    • PathFinder II results may also be tracked over time to monitor changes in probabilities.
    Show more
    Close
    masterfit contact lens software

    MasterFit Contact Lens Software

    MasterFit™ Contact Lens Software helps streamline the fitting of gas permeable (GP) lenses.

    Corneal conditions such as asymmetrical astigmatism, a decentered apex, contact lens warpage, and irregular, peripheral and central astigmatism can dramatically affect the way a contact lens behaves on the eye. MasterFit II allows customized fitting of GP lenses according to your own fitting preferences.

    • Simulate fluorescein patterns for custom and stock lenses, including spherical, toric, and aspheric designs
    • Automatically design lenses to your preferences by customizing fitting options such as desired tear film clearance
    • Improve trial lens fitting efficiency by adjusting lens parameters, such as peripheral curves, and simulating lens movement to compensate for lens-to-cornea relationship
    • Email lens design and topography exam to your lab for efficient ordering and fulfillment

    Laptop Atlas Software

    Atlas Review Software

    Greater productivity through connectivity

    Atlas Review Software is a high-value tool for existing Atlas Model 993, 995 and 9000 users which allows you to get more out of your Atlas Corneal Topography System. This new software builds upon the previous Atlas tools that clinicians have come to trust, while providing a range of added functionality.

    • Dynamic remote access to all your corneal topography exam data and patient education tools, such as corneal wavefront simulation
    • Increases instrument availability for improved patient workflow
    • Equivalent software functionality as the Atlas Model 9000
    • Compatible with Atlas Models 993 and 9953

     

  • ATLAS 9000 Series Support
    MASTERVUE SOFTWARE DOWNLOAD
    The following are the current versions of MasterVue software:
    Topographer Model Number* Current Version Download
    991
    992
    993
    995
    A12.2
    Date: 04/2006
    Read instructions and begin download.
    910
    920
    990
    A10.1
    Date: 12/1999
    US: Call Carl Zeiss Meditec Customer Care at (877) 486-7473.
    International: Search contacts
    * The model number is the first three (3) digits of your serial number.
    OPTIONAL SOFTWARE MODULES
    Optional software modules may also need to be upgraded according to the table below:
    Previously Installed Optional Software Module Installation Instructions
    MasterFit™ Read instructions and begin download.
    Advanced Refractive Diagnostic Module (ARDM) No action needed. Automatically upgraded with MasterVue A12.2.
    PathFinder™ No action needed. Automatically upgraded with MasterVue A12.2.
    Healing Trend/STARS No action needed. Automatically upgraded with MasterVue A12.2.
    Simulated Ablation No action needed. Automatically upgraded with MasterVue A12.2.
    VisionPro™ Must be reinstalled. In the US, contact Carl Zeiss Meditec at (877) 486-7473 for more information. International: Search contacts
    Paragon CRT Lens Selection Software No action needed.

    DOCUMENTATION UPDATES
    A new chapter 14 on PathFinder Corneal Analysis is available for your ATLAS User's Guide (614 kB, Date: 02/2003).

    Atlas 9000 system software

    MASTERVUE SYSTEM SOFTWARE VERSION A12.2
    (Date: 04/2006) Installation Instructions

    Software Information
    The software update improves overall system integrity and is required in order to install third-party applications such at Paragon's CRT Corneal Refractive Therapy software module.

    DOWNLOAD (9.2 MB)

    Installation Requirements:

    • Topographer Models 991, 992, 993, or 995 only.
    • MasterVue Version A10.1 or later or G8 (German Language Version)
    • 7 formatted 3.5" floppy disks.
    • A minimum of 10 MB disk space on your PC.


    NOTE: If you are unable to transfer files to 3.5" floppy disks, contact
    US: Call Carl Zeiss Meditec Customer Service at (877) 486-7473.
    International: Search contacts

    Show more
    Close

    Installation Instructions on your PC:

    1. Click the Download button on this page to start the download.
    2. Select Save to save the program to disk.
    3. Run the .exe file that you saved.
    4. Follow the instructions on the screen to create the floppy installation disks.

    Show more
    Close

    Installation Instructions on your Topographer:

    • Make sure you have a current backup of your patient data before proceeding with this section.

    • Installation of version A12.2 over version G8 requires that the user install using the Windows® "Start/Run" command.

    1. From the Main Menu select Utilities.
    2. On the Utilities form select Install.
    3. Insert MasterVue Disk 1 of 7 into drive a: and then select OK.
    4. The following message will appear: "Windows will restart now. MasterVue Setup will continue after system reboots".
    5. Select OK.
    6. After the system reboots, the following message will appear:
      "Select the language for this installation from the choices below".
    7. Select English or Deutsch and the OK button.
    8. The MasterVue System software will prepare the InstallShield wizard and begin the setup process.
    9. Follow the instructions to complete the installation with disks 2 through 7.
    10. The following message will appear: "Optional module software can be installed using the Install button on the Utilities Screen."
    11. The following message will appear: "The setup will now exit and restart Windows. Please remove the setup diskette from the drive. If the system fails to restart properly, you may need to turn off power and on again to continue."
    12. Remove the disk and select OK.

    DOWNLOAD (9.2 MB)

    Show more
    Close
  • Services

    Financial Solutions from ZEISS

    The smart way to acquire ZEISS technology

    Want the latest technology from ZEISS despite a tight budget? ZEISS Financial Solutions might have the right financing options for you.

    More about ZEISS Financial Solutions

    Benefit from our customer care packages

    Register for a Service Contract

Discover more

Sales Request

Any questions about buying our products?

Contact us now

Price Request

Our Sales Team will contact you shortly.

Request a Quote

Schedule your Consultation

Our experts will contact you shortly.

Schedule an Appointment

Customer Care

Need assistance with your product?

Contact us now

Related Products