Humphrey Field Analyzer 3 - The Gold Standard In Perimetry
innovationMADE BY ZEISS
Streamlining your clinic flow. ZEISS Humphrey Field Analyzer (HFA3)
innovationMADE BY ZEISS
Humphrey Field Analyzer 3 - The Gold Standard In Perimetry
Reaching new heights with the gold standard of perimetry. ZEISS Humphrey Field Analyzer (HFA3)

Schedule your Consultation

Humphrey Field Analyzer – HFA3 Visual Field Series

  • Highlights

    Introducing the NEW ZEISS Humphrey Field Analyzer 3

    The best just got better

    The new Humphrey Field Analyzer 3 (HFA3), with Liquid Lens technology, combines everything you’ve always valued in a perimeter with everything you’ve been waiting for. See for yourself.

    Loading the player...
    Humphrey Visual Field Analyzer 3

    NEW Humphrey Field Analyzer – HFA3 Visual Field Series

    HFA3 provides a streamlined and faster workflow with an array of remarkable new features designed to:

    • Reduce setup time with a single trial lens. Using liquid pressure, the new Liquid Trial Lens™, instantly delivers each patient's refractive correction, with the touch of a button.1
    • Save time with an intuitive new SmartTouch™ interface that helps to shorten chair time.
    • Accelerate clinic flow with equipment that can be learned quickly and operated easily.
    • Improve confidence in visual field test results with RelEYE™. Instantly review the patient's eye position, at any stimulus point.
    • Gain peace of mind with seamless transferability of legacy data from the HFA II and HFA II-i  to HFA3.
    • Easy to use kinetic graphical user interface with full 180° visual field testing range.
    Humphrey Visual Field Analyzer 3 - Liquid Trial Lens

    Liquid Lens technology: One lens, less time

    The new automatic Liquid Trial Lens reduces patient setup time by automatically loading the patient’s refractive correction from their previous exam. The result is faster patient flow and reduced chance of error when selecting a lens during test setup.

    Humphrey Visual Field Analyzer 3 - SmartTouch Interface

    SmartTouch interface: Ready, set, test!

    The new HFA3 platform gets you up and running with fewer touches – simply select the patient’s name and press Start, all using an all-new color graphic user interface.

    Exclusive gaze tracking: On track? Know right now

    Save time with improved gaze tracking initialization.

    Kinetic Perimetry: Significant advancements

    Easy to use kinetic graphical user interface with full 180° testing range.


    Combined Reports: See the whole picture

    ZEISS FORUM allows the HFA3 to work with ZEISS CIRRUS HD-OCT or CIRRUS photo to generate structure/function combined reports in a single display.

    HFA review with FORUM Glaucoma Workplace from ZEISS

    • Review quantitative and qualitative information from all standard HFA analyses, in an easy-to-read format
    • Change baselines and capture, track and measure progression simply and easily with Guided Progression Analysis™ (GPA™)
    • Use RelEYE to preserve an image of the patient’s eye at every stimulus presentation during a SITA™ Standard test
    • Check for ptosis or trial lens rim artifacts as well as assess patient's compliance with RelEYE in both GPA and single-field analysis modes
    • Work with either Mean Deviation (MD) or Visual Field Index™ (VFI™)—or both
    • Generate HFA reports using a MAC or a PC

    Humphrey Gold Standards

    For years, the Humphrey Field Analyzer has brought certainty to glaucoma diagnosis. As the gold standard of perimetry, it is a critical diagnostic partner in thousands of practices. HFA delivers the interactive analysis you need, when and where you need it.

    • Visual Field Index (VFI) – VFI is a simple and intuitive global index. Its most powerful application is GPA, which trends VFI over time to project remaining vision.
    • GPA Alert – A message in simple language that indicates whether statistically significant deterioration was identified in consecutive visits.
    • STATPAC™ – The language of perimetry, STATPAC compares results to proprietary age normative and glaucoma databases.
    • SITA™ Strategies – Unsurpassed in efficiency, SITA is patient responsive: it learns to perform as fast as the patient.
    • Connectivity – HFA3 connects to other HFA3 and HFA II- perimeters. For comprehensive connectivity, HFA3 can be connected to FORUM with FORUM Glaucoma Workplace. HFA3 also supports common file folder sharing used by most Electronic Medical Record Systems (EMRs).
  • Technical Data
    HFA3 Technical Specifications
    830
    840
    850
    860
    Test Specifications

    Maximum temporal range (degrees)

    90

    Stimulus duration

    200 ms

    Visual field testing distance

    30 cm

    Background illumination

    31.5 ASB
    Threshold test library

    24-2, 30-2, 10-2, Macula




    60-4, Nasal step





    Threshold test strategy

    SITA Standard, SITA Fast, Full Threshold, FastPac





    SITA-SWAP



    Suprathreshold test library

    C40, C76, C80




    C64, C-Armaly





    Peripheral test patterns





    Suprathreshold test modes

    Age corrected


    Threshold related, Single intensity

    Specialty test library

    Social Security Disability, monocular, binocular

    Esterman monocular, binocular, superior 36, 64

    Kinetic testing

    Custom Kinetic testing




    Custom Static testing





    Operator interface

    Touch-screen CRT with keyboard





    Fixation control

    Heijl Krakau blind spot monitor





    Video eye monitor





    Gaze tracking

     


    Head tracking

     


    Vertex monitoring

       

    Stimulus

    White-on-white





    Red- or blue-on-white

     


    Blue-on-yellow (SITA SWAP)

       

    General Testing Features

    Stimulus sizes

    Goldmann I-V
    Goldmann I-V
    Goldmann I-V
    Goldmann I-V

    Foveal threshold testing

     

    Automatic pupil measurement

     

    Liquid Trial Lens (AutoTLC)

         

    RelEYE eye review

       
    Test storage

    User-defined





    Software features

    Single Field Analysis (SFA)


    Glaucoma Hemifield Test (GHT)


    Visual Field Index (VFI)


    Guided Progression Analysis (GPA)


    Serial field overview



    Networking



    FORUM Connectivity


    DICOM Connectivity



    Data storage, retrieval and analysis
           

    Hard drive

    500GB
    500GB
    500GB
    500GB

    USB


    Printer
    Native postscript printer support for network capable printers
    Dimensions

    Height

    23“ (58 cm)

    Width

    20“ (51 cm)
    Electrical requirements 100-120V~, 50/60Hz, 4.0A
    230V~, 50/60Hz, 1.8A
    Standards UL, CSA, and CE standards
  • Technical Support

    ZEISS HFA3 Setup Configuration Table

    The table below summarizes the output configurations for HFA3.
    Click on the “Configuration Instructions” link to view detailed set up instructions. 
     

    Connectivity Goal SW Required Connection Type Output Format/Protocol Use Example Configuration Instructions
    EMR Connection by Company EMR Connectivity list EMR Connectivity list EMR Connectivity list EMR Connectivity list Download
    Network Shared Folder HFA3 Version 1.0 or greater Network Folder PDF or TIF NextGen, Compulink, Mdoffice, Integrity Download
    Non-DICOM EMR HFA3 Version 1.1 or greater Network Folder CZM-XML and PDF or TIF Officemate, MaximEyes Download
    DICOM EMR HFA3 Version 1.2 or greater Ethernet / Port (FEP not supported) DICOM MedFlow, VistA (VA) Download
    Domain Set Up HFA3 Version 1.1 or greater Ethernet / Port N/A Add HFA3 to Domain Download
    FORUM® and FORUM Glaucoma Workplace

    HFA3 Version 1.0 or greater

    Note: FORUM Archive and Server must be at version 3.2 or greater, and include Forum Glaucoma Workplace 2.0.3 or greater.

    Ethernet / Port DICOM FORUM and FORUM Glaucoma Workplace; integration with HL7 based EMR Download
    Sharing HFA3 data with HFA™ II-i devices  HFA3 Version 1.0 or greater Ethernet / Port to FORUM DICOM HFAII-i and HFA3 data stored and retrieved from FORUM Archive database Download
  • Video/ Webinar

    Product Information

    Introducing the NEW ZEISS Humphrey Field Analyzer 3

    The best just got better

    The new Humphrey Field Analyzer 3 (HFA3), with Liquid Lens technology, combines everything you’ve always valued in a perimeter with everything you’ve been waiting for. See for yourself.

    Loading the player...

    Webinars

    Loading the player...

    Effective Perimetry Series - Session 1

    A General Introduction to the Art and Practice of Perimetry

    Harry A. Quigley, MD
    A. Edward Maumenee Professor of Ophthalmology
    Director, Glaucoma Center of Excellence
    Wilmer Eye Institute, Johns Hopkins University

    Loading the player...

    Effective Perimetry Series - Session 2

    STATPAC and the Analysis of Single Fields

    Harry A. Quigley, MD
    A. Edward Maumenee Professor of Ophthalmology
    Director, Glaucoma Center of Excellence
    Wilmer Eye Institute, Johns Hopkins University

    Loading the player...

    Effective Perimetry Series - Session 3

    Glaucomatous Visual Fields

    Nathan M. Radcliffe, MD
    Assistant Professor of Ophthalmology
    Weill Cornell Medical College

    Loading the player...

    Effective Perimetry Series - Session 4

    Integrating Structural and Functional Measurements

    Steven D. Vold, MD
    Vold Vision, LLC

    Loading the player...

    Effective Perimetry Series - Session 5

    Choosing a Visual Field Test

    Murray Fingeret, OD, FAAO
    Clinical Professor, SUNY College of Optometry
    Chief, Optometry Section,
    Dept of Veterans Affairs, NYHHCS

    Loading the player...

    Effective Perimetry Series - Session 6

    Artifactual Test Results in Visual Field Testing

    Chris A. Johnson, MSc, PhD, Dsc
    Professor of Ophthalmology & Visual Sciences
    University of Iowa, Carver College of Medicine

  • Services

    OPTIME from ZEISS

    Support whenever you need it

    Do you rely on high system availability? If your answer is yes, then why not consider our ZEISS OPTIME service agreements, which are designed to ensure the readiness of your medical equipment at all times.

    More about ZEISS OPTIME

    REMOTE Service from ZEISS

    Expert assistance from afar

    Do you need immediate service support? ZEISS Remote Service offers online support for customers with ZEISS OPTIME advanced and ZEISS OPTIME complete agreements.

    More about ZEISS Remote Service

    Financial Solutions from ZEISS

    The smart way to acquire ZEISS technology

    Want the latest technology from ZEISS despite a tight budget? ZEISS Financial Solutions might have the right financing options for you.

    More about ZEISS Financial Solutions

    Benefit from our customer care packages

    Register for a Service Contract
  • Downloads

    FORUM Glaucoma Workplace 2.0 from ZEISS

    Clinical Interpretation Guide

    Page(s): 24
    Filesize: 1,807 kB

    Humphrey Field Analyzer from ZEISS

    Compendium of peer-reviewed, published clinical articles

    Page(s): 28
    Filesize: 558 kB

    The best just got better

    NEW HFA3 with Liquid Lens Technology

    Page(s): 10
    Filesize: 5,002 kB

    Humphrey Visual Field Analyzers

    Innovation and connectivity

    Page(s): 14
    Filesize: 1,039 kB

Discover more

Sales Request

Any questions about buying our products?

Contact us Now

Price Request

Our Sales Team will contact you shortly.

Request a Quote

Schedule your Consultation

Our experts will contact you shortly.

Schedule an Appointment

Customer Care

Need assistance with your product?

Contact us now

Related Products

  • 1 Liquid Trial Lens available correction range is -8 to +8 diopters sphere. Spherical correction only. Liquid Trial Lens available on the HFA3 model 860.
We use cookies on this site. Cookies are small text files that are stored on your computer by websites. Cookies are widely used and help to optimize the pages that you view. By using this site, you agree to their use. more