Humphrey Field Analyzer 3 - The Gold Standard In Perimetry
INNOVATIONMADE BY ZEISS
Accelerate your clinic flow. ZEISS HFA3 with SITA Faster

Schedule your Consultation

INNOVATIONMADE BY ZEISS
Cheetah running
The best just got faster. ZEISS HFA3 with SITA Faster

Humphrey Field Analyzer – HFA3 Visual Field Series

  • Highlights

    ZEISS Humphrey Field Analyzer 3 now with SITA Faster

    The best just got faster

    The Humphrey Field Analyzer 3 (HFA3) combines everything you’ve always valued in a Humphrey with more than you could imagine to streamline your workflow. 

    Loading the player...

    NEW Humphrey Field Analyzer – HFA3 Visual Field Series

    HFA3 provides a streamlined and faster workflow with an array of remarkable new features designed to:

    • Reduce visual field testing time with NEW SITA™ Faster.
    • Mixed Guided Progression Analysis™ (GPA™): Inter-mixing of SITA Standard, SITA Fast, and SITA Faster.
    • Reduce setup time with a single trial lens. Using liquid pressure, the new Liquid Trial Lens™ instantly delivers each patient’s refractive correction with the touch of a button.*
    • Improve confidence in test results with RelEYE™**. Instantly review the patient’s eye position, at any stimulus point.
    • Simplify operation with the intuitive new SmartTouch™ interface that novice users will appreciate.
    • Gain peace of mind with seamless transferability of legacy data from the HFA II and HFA II-i to the HFA3.
    • SITA Faster test is about half the time of SITA Standard and 70% of SITA Fast with the same reproducibility as SITA Fast. This may improve patient satisfaction with perimetric testing and reduce patient fatigue.
    • Mixed GPA allows free mixing of SITA Faster, SITA Fast and SITA Standard and allows full access to the patient’s progression analysis including all SITA tests.
    Humphrey Visual Field Analyzer 3 - Liquid Trial Lens

    Liquid Lens technology

    Liquid Lens technology allows you to automatically load each patient’s refractive correction from the previous exam.

    Humphrey Visual Field Analyzer 3 - SmartTouch Interface

    SmartTouch interface

    SmartTouch interface on the HFA3 platform gets you up and running with fewer touches. Simply select the patient's name and press start, all using a color graphic user interface. 

    Exclusive gaze tracking: On track? Know right now

    Save time with improved gaze tracking initialization.

    Kinetic Perimetry: Significant advancements

    Easy to use kinetic graphical user interface with full 180° testing range.


    Combined Reports: See the whole picture

    ZEISS FORUM allows the HFA3 to work with ZEISS CIRRUS HD-OCT or CIRRUS photo to generate structure/function combined reports in a single display.
    HFA Dual Baseline Report

    HFA Dual Baseline Report

    HFA Dual Baseline Report
    HFA Structure-Function Guided Progression Analysis Report

    HFA Structure-Function Guided Progression Analysis Report

    HFA Structure-Function Guided Progression Analysis Report

    Review the complete HFA exam history with Glaucoma Workplace***

    Advanced, interactive review of all standard HFA analyses and GPA, including:

    • Mixed GPA
    • Trend analysis by superior vs. inferior hemifield
    • 10-2 MD trend analysis
    • Dual baselines
    • Dynamic Structure-Function GPA for both HFA and CIRRUS on a single screen
    • Clinical Events indicate timing of intervention and initiation of new trend analysis
    • Color-coded alerts help you quickly identify statistically significant change
    • View HFA and CIRRUS information efficiently displayed in simple side-by-side format


    Humphrey Gold Standards

    For years, the Humphrey Field Analyzer has brought certainty to glaucoma diagnosis. As the gold standard of perimetry, it is a critical diagnostic partner in thousands of practices. HFA delivers the interactive analysis you need, when and where you need it.

    • Visual Field Index (VFI) – VFI is a simple and intuitive global index. Its most powerful application is GPA, which trends VFI over time to project remaining vision.
    • GPA Alert – A message in simple language that indicates whether statistically significant deterioration was identified in consecutive visits.
    • STATPAC™ – The language of perimetry, STATPAC compares results to proprietary age normative and glaucoma databases.
    • SITA™ Strategies – Unsurpassed in efficiency, SITA is patient responsive: it learns to perform as fast as the patient.
    • Connectivity –  For comprehensive connectivity, HFA3 can be connected to FORUM with Glaucoma Workplace. HFA3 also supports common file folder sharing used by most Electronic Medical Record Systems (EMRs).

    * Available correction range is -8 to +8 diopters sphere. Spherical correction only. Liquid Trial Lens available on the HFA3 model 860.

    ** RelEYE is available on both the instrument and through Glaucoma Workplace.

    *** ZEISS FORUM and Glaucoma Workplace are required.

  • Technical data
    HFA3 Technical Specifications
    830
    840
    850
    860
    Test Specifications

    Maximum temporal range (degrees)

    90

    Stimulus duration

    200 ms

    Visual field testing distance

    30 cm

    Background illumination

    31.5 ASB
    Threshold test library

    24-2, 30-2, 10-2, Macula




    60-4, Nasal step





    Threshold test strategy

    SITA Standard, SITA Fast and SITA Faster, Full Threshold, FastPac





    SITA-SWAP

       

    Suprathreshold test library

    C40, C76, C80




    C64, C-Armaly





    Peripheral test patterns





    Suprathreshold test modes

    Age corrected


    Threshold related, Single intensity

    Specialty test library

    Social Security Disability, monocular, binocular

    Esterman monocular, binocular, superior 36, 64

    Kinetic testing

     

    Custom Kinetic testing

     


    Custom Static testing





    Operator interface

    Touch-screen CRT with keyboard





    Fixation control

    Heijl Krakau blind spot monitor





    Video eye monitor





    Gaze tracking

     


    Head tracking

     


    Vertex monitoring

       

    Stimulus

    White-on-white





    Red- or blue-on-white

     


    Blue-on-yellow (SITA SWAP)

       

    General Testing Features

    Stimulus sizes

    Goldmann I-V
    Goldmann I-V
    Goldmann I-V
    Goldmann I-V

    Foveal threshold testing

     

    Automatic pupil measurement

     

    Liquid Trial Lens (AutoTLC)

         

    RelEYE eye review

       
    Test storage

    User-defined





    Software features

    Single Field Analysis (SFA)


    Glaucoma Hemifield Test (GHT)


    Visual Field Index (VFI)


    Guided Progression Analysis (GPA)


              Mixed GPA

    Serial field overview



    Networking



    FORUM Connectivity


    DICOM Connectivity



    Data storage, retrieval and analysis
           

    Hard drive

    500GB
    500GB
    500GB
    500GB

    USB


    Printer
    Native postscript printer support for network capable printers
    Dimensions

    Height

    23“ (58 cm)

    Width

    20“ (51 cm)
    Electrical requirements 100-120V~, 50/60Hz, 4.0A
    230V~, 50/60Hz, 1.8A
    Standards UL, CSA, and CE standards
  • Videos / Webinars

    Product Information

    Loading the player...

    ZEISS Humphrey Field Analyzer 3 now with SITA Faster

    The best just got faster

    Testimonial

    Loading the player...

    Visual Field Testing with SITA Faster

    Dr. Vincent Michael Patella discusses SITA Faster

    Webinars

    Loading the player...

    Effective Perimetry Series - Session 1

    A General Introduction to the Art and Practice of Perimetry

    Harry A. Quigley, MD
    A. Edward Maumenee Professor of Ophthalmology
    Director, Glaucoma Center of Excellence
    Wilmer Eye Institute, Johns Hopkins University

    Loading the player...

    Effective Perimetry Series - Session 2

    STATPAC and the Analysis of Single Fields

    Harry A. Quigley, MD
    A. Edward Maumenee Professor of Ophthalmology
    Director, Glaucoma Center of Excellence
    Wilmer Eye Institute, Johns Hopkins University

    Loading the player...

    Effective Perimetry Series - Session 3

    Glaucomatous Visual Fields

    Nathan M. Radcliffe, MD
    Assistant Professor of Ophthalmology
    Weill Cornell Medical College

    Loading the player...

    Effective Perimetry Series - Session 4

    Integrating Structural and Functional Measurements

    Steven D. Vold, MD
    Vold Vision, LLC

    Loading the player...

    Effective Perimetry Series - Session 5

    Choosing a Visual Field Test

    Murray Fingeret, OD, FAAO
    Clinical Professor, SUNY College of Optometry
    Chief, Optometry Section,
    Dept of Veterans Affairs, NYHHCS

    Loading the player...

    Effective Perimetry Series - Session 6

    Artifactual Test Results in Visual Field Testing

    Chris A. Johnson, MSc, PhD, Dsc
    Professor of Ophthalmology & Visual Sciences
    University of Iowa, Carver College of Medicine

  • Services

    OPTIME from ZEISS

    Support whenever you need it

    Do you rely on high system availability? If your answer is yes, then why not consider our ZEISS OPTIME service agreements, which are designed to ensure the readiness of your medical equipment at all times.

    More about ZEISS OPTIME

    REMOTE Service from ZEISS

    Expert assistance from afar

    Do you need immediate service support? ZEISS Remote Service offers online support for customers with ZEISS OPTIME advanced and ZEISS OPTIME complete agreements.

    More about ZEISS Remote Service

    Financial Solutions from ZEISS

    The smart way to acquire ZEISS technology

    Want the latest technology from ZEISS despite a tight budget? ZEISS Financial Solutions might have the right financing options for you.

    More about ZEISS Financial Solutions

    Benefit from our customer care packages

    Register for a Service Contract
  • Downloads

    Humphrey Field Analyzer 3 from ZEISS

    The best just got faster

    Page(s): 10
    Filesize: 6,324 kB

    Humphrey Field Analyzer from ZEISS

    Compendium of peer-reviewed, published clinical articles

    Page(s): 28
    Filesize: 558 kB

Discover more

Sales Request

Any questions about buying our products?

Contact us now

Price Request

Our Sales Team will contact you shortly.

Request a Quote

Schedule your Consultation

Our experts will contact you shortly.

Schedule an Appointment

Customer Care

Need assistance with your product?

Contact us now

Related Products

We use cookies on this site. Cookies are small text files that are stored on your computer by websites. Cookies are widely used and help to optimize the pages that you view. By using this site, you agree to their use. more