Humphrey Field Analyzer 3 - The Gold Standard In Perimetry

Humphrey Field Analyzer 3

The Gold Standard of Perimetry Reaches New Heights

Humphrey Field Analyzer – HFA3 Visual Field Series

  • Highlights

    Introducing the NEW ZEISS Humphrey Field Analyzer 3

    The best just got better

    The new Humphrey Field Analyzer 3 (HFA3), with Liquid Lens technology, combines everything you’ve always valued in a perimeter with everything you’ve been waiting for. 

               

    Loading the player...
    Humphrey Visual Field Analyzer 3

    NEW Humphrey Field Analyzer – HFA3 Visual Field Series

    HFA3 provides a streamlined and faster workflow with an array of remarkable new features designed to:

    • Reduce setup time with a single trial lens. Using liquid pressure, the new Liquid Trial Lens™, instantly delivers each patient's refractive correction, with the touch of a button.*
    • Save time with an intuitive new SmartTouch™ interface that helps to shorten chair time.
    • Accelerate clinic flow with equipment that can be learned quickly and operated easily.
    • Improve confidence in visual field test results with RelEYE™. Instantly review the patient's eye position, at any stimulus point.
    • Gain peace of mind with seamless transferability of legacy data from the HFA II and HFA II-i  to HFA3.
    • Easy to use kinetic graphical user interface with full 180° visual field testing range.
    Humphrey Visual Field Analyzer 3 - Liquid Trial Lens

    Liquid Lens technology: One lens, less time

    The new automatic Liquid Trial Lens reduces patient setup time by automatically loading the patient’s refractive correction from their previous exam. The result is faster patient flow and reduced chance of error when selecting a lens during test setup.

    Humphrey Visual Field Analyzer 3 - SmartTouch Interface

    SmartTouch interface: Ready, set, test!

    The new HFA3 platform gets you up and running with fewer touches – simply select the patient’s name and press Start, all using an all-new color graphic user interface.

    Exclusive gaze tracking: On track? Know right now

    Save time with improved gaze tracking initialization.

    Kinetic Perimetry: Significant advancements

    Easy to use kinetic graphical user interface with full 180° testing range.


    HFA review with FORUM Glaucoma Workplace from ZEISS

    • Review quantitative and qualitative information from all standard HFA analyses, in an easy-to-read format
    • Change baselines and capture, track and measure progression simply and easily with Guided Progression Analysis™ (GPA™)
    • Use RelEYE to preserve an image of the patient’s eye at every stimulus presentation during a SITA™ Standard test
    • Check for ptosis or trial lens rim artifacts as well as assess patient's compliance with RelEYE in both GPA and single-field analysis modes
    • Work with either Mean Deviation (MD) or Visual Field Index™ (VFI™)—or both
    • Generate HFA reports using a MAC or a PC

    Humphrey Gold Standards

    For years, the Humphrey Field Analyzer has brought certainty to glaucoma diagnosis. As the gold standard of perimetry, it is a critical diagnostic partner in thousands of practices. HFA delivers the interactive analysis you need, when and where you need it.

    • Visual Field Index (VFI) – VFI is a simple and intuitive global index. Its most powerful application is GPA, which trends VFI over time to project remaining vision.
    • GPA Alert – A message in simple language that indicates whether statistically significant deterioration was identified in consecutive visits.
    • STATPAC™ – The language of perimetry, STATPAC compares results to proprietary age normative and glaucoma databases.
    • SITA™ Strategies – Unsurpassed in efficiency, SITA is patient responsive: it learns to perform as fast as the patient.
    • Connectivity – HFA3 connects to other HFA3 and HFA II- perimeters. For comprehensive connectivity, HFA3 can be connected to FORUM with FORUM Glaucoma Workplace. HFA3 also supports common file folder sharing used by most Electronic Medical Record Systems (EMRs).

    *Liquid Trial Lens available correction range is -8 to +8 diopters sphere. Spherical correction only. Liquid Trial Lens available on the HFA3 model 860.

  • Technical Data
    HFA3 Technical Specifications
    840
    850
    860
    Test Specifications

    Maximum temporal range (degrees)

    90

    Stimulus duration

     200 ms

    Visual field testing distance

    30 cm 

    Background illumination

     31.5 ASB
    Threshold test library

    24-2, 30-2, 10-2, Macula




    60-4, Nasal step




    Threshold test strategy

    SITA Standard, SITA Fast, Full Threshold, FastPac




    SITA-SWAP

     

    Suprathreshold test library

    C40, C76, C80




    C64, C-Armaly




    Peripheral test patterns




    Suprathreshold test modes

    Age corrected


    Threshold related, Single intensity

    Specialty test library

    Social Security Disability, monocular, binocular

     

    Esterman monocular, binocular, superior 36, 64

    Kinetic testing

     

    Custom Kinetic testing

     

    Custom Static testing




    Operator interface

    Touch-screen CRT with keyboard




    Fixation control

    Heijl Krakau blind spot monitor




    Video eye monitor




    Gaze tracking




    Head tracking




    Vertex monitoring

     

    Stimulus

    White-on-white




    Red- or blue-on-white




    Blue-on-yellow (SITA SWAP)

     

    General Testing Features

    Stimulus sizes

    Goldmann I-V
    Goldmann I-V
    Goldmann I-V

    Foveal threshold testing



    Automatic pupil measurement

    Liquid Trial Lens (AutoTLC)

       

    RelEYE eye review

     
    Test storage

    User-defined




    Software features

    Single Field Analysis (SFA)

    Glaucoma Hemifield Test (GHT)

    Visual Field Index (VFI)

    Guided Progression Analysis (GPA)

    Serial field overview


    Networking


    FORUM Connectivity

    DICOM Connectivity


    Data storage, retrieval and analysis
         

    Hard drive

    500GB
    500GB
    500GB

    USB

    Printer
    Native postscript printer support for network capable printers
    Dimensions

    Height

    23“ (58 cm)

    Width

    20“ (51 cm)

    Depth

    18“ (46 cm)

    Weight

    63 lbs (28.7 kg)
    Electrical requirements 100-120V~, 50/60Hz, 4.0A
    230V~, 50/60Hz, 1.8A
    Standards UL, CSA, and CE standards
  • Video/ Webinar

    Product Information

    Introducing the NEW ZEISS Humphrey Field Analyzer 3

    The best just got better

    The new Humphrey Field Analyzer 3 (HFA3), with Liquid Lens technology, combines everything you’ve always valued in a perimeter with everything you’ve been waiting for. See for yourself.

    Loading the player...

    Webinars

    Loading the player...

    Effective Perimetry Series - Session 1

    A General Introduction to the Art and Practice of Perimetry

    Harry A. Quigley, MD
    A. Edward Maumenee Professor of Ophthalmology
    Director, Glaucoma Center of Excellence
    Wilmer Eye Institute, Johns Hopkins University

    Loading the player...

    Effective Perimetry Series - Session 2

    STATPAC and the Analysis of Single Fields

    Harry A. Quigley, MD
    A. Edward Maumenee Professor of Ophthalmology
    Director, Glaucoma Center of Excellence
    Wilmer Eye Institute, Johns Hopkins University

    Loading the player...

    Effective Perimetry Series - Session 3

    Glaucomatous Visual Fields

    Nathan M. Radcliffe, MD
    Assistant Professor of Ophthalmology
    Weill Cornell Medical College

    Loading the player...

    Effective Perimetry Series - Session 4

    Integrating Structural and Functional Measurements

    Steven D. Vold, MD
    Vold Vision, LLC

    Loading the player...

    Effective Perimetry Series - Session 5

    Choosing a Visual Field Test

    Murray Fingeret, OD, FAAO
    Clinical Professor, SUNY College of Optometry
    Chief, Optometry Section,
    Dept of Veterans Affairs, NYHHCS

    Loading the player...

    Effective Perimetry Series - Session 6

    Artifactual Test Results in Visual Field Testing

    Chris A. Johnson, MSc, PhD, Dsc
    Professor of Ophthalmology & Visual Sciences
    University of Iowa, Carver College of Medicine

  • Services
    Customer Care

    Customer Care

    Every facet of Customer Care at ZEISS is designed to protect your investment in your equipment. Whether it is a high-end surgical microscope, an ophthalmic laser, or diagnostic equipment, we provide timely, responsive services through a national network of highly skilled technicians.

    Our dedication to providing the highest quality of customer care is reflected by the fact that our customers consistently rank us superior in terms of their satisfaction with our performance.

  • More Information

    Humphrey Field Analyzer 3 from ZEISS

    The best just got better

    Page(s): 10
    File size: 4,989 kB

    Humphrey Field Analyzer from ZEISS

    Compendium of peer-reviewed, published clinical articles

    Page(s): 28
    File size: 558 kB

    FORUM Glaucoma Workplace from ZEISS

    Clinical Interpretation Guide

    Page(s): 10
    File size: 833 kB

    ZEISS Humphrey Field Analyzer HFA3: Improving on a Standard

    Page(s): 2
    File size: 528 kB

Related Products

We use cookies on this site. Cookies are small text files that are stored on your computer by websites. Cookies are widely used and help to optimize the pages that you view. By using this site, you agree to their use. more