Product Family

ZEISS 3-piece IOLs

Reliable monofocal hydrophobic IOL performance

ZEISS 3-piece IOLs are available in a spheric (CT LUCIA 202) and an aspheric (CT LUCIA 602)* version. Both featuring highly stable PVDF haptics, designed to ensure IOL stability in the capsular bag. CT LUCIA® 3-piece IOLs from ZEISS are glistening-free1,2 and have a 360° square edge design for a low PCO rate3.

*Available in the US only
  

  • High corrected visual acuity
  • Good refractive results
  • Low inflammatory reaction

Designed to ensure IOL stability in the capsular bag

ZEISS 3-piece IOLs are designed for cases when IOL stability in the capsular bag is challenging. Providing consistently high corrected visual acuity1, achieving good and precise refractive results2, ensuring low rate of early post-operative Nd:YAG capsulotomies2 and enabling low inflammatory reaction.1

  • ZEISS CT LUCIA 202

    Monofocal IOL with 360° square-edge design

    • Monofocal, spherical
    • PVDF haptics designed for better capsular bag stability and to eliminate capsular bag stretching
    • 360° square-edge design to reduce PCO
  • ZEISS CT LUCIA 602

    Monofocal, aspheric IOL

    • Monofocal, aspheric
    • PVDF haptics designed for better capsular bag stability and to eliminate capsular bag stretching
    • 360° square-edge design to reduce PCO
    • Featuring the patented ZO Asphericity Concept (ZO: ZEISS Optic)⁴ designed to compensate for a range of aberrations, providing better image quality in real-life conditions
    • Available in the US only

High corrected visual acuity¹

The high stability of the lens in the capsular bag together with its good positioning behaviour supporting good visual outcome after surgery.

Good refractive results²

The reliable performance of the lens after surgery when it comes to IOL stability in the capsular bag as well as low amount of post-surgery complications ensuring good refractive results of the lens.

Low inflammatory reaction¹

The safety of the lens after implantation proved to be very re-ensuring with low rates of post- surgery events. Inflammatory reaction were minimal and mostly related to the procedure itself and not to the IOL.

Handling instruction videos

  • ZEISS CT LUCIA 202

  • ZEISS CT LUCIA 602

Downloads

    • CT LUCIA 202 Datasheet EN

      Pages: 2
      File size: 102 KB
    • CT LUCIA 602 Datasheet US

      Pages: 4
      File size: 956 KB
    • CT LUCIA 202 DualTec Injector Image EN

      Pages: 1
      File size: 7 MB
    • CT LUCIA 602 Handling Instructions US

      Pages: 2
      File size: 355 KB

Specification comparison

ZEISS CT LUCIA IOL 3-piece family

CT LUCIA® 202
CT LUCIA® 602
Optic Design
Monofocal, spheric
Monofocal, aspheric
Material
Hydrophobic acrylic
Hydrophobic acrylic with Polyvinylidene fluoride (PVDF) monofilament haptics
Optic Diameter
6.0 mm
6.0 mm
Total Diameter
13.0 mm
13.0 mm
Haptic Angulation
Lens Design
Three-piece
Three-piece
Incision Size
2.8 mm
2.8 mm
Company Labeled A-Constant⁵
118.2
117.7
Diopter Range
From +4.0 to +34.0 D, 0.5 D increments
From +4.0 to +34.0 D, 0.5 D increments
ACD⁶
5.1
4.8
Abbe
50
50
Implantation in
Capsular bag
Bag
Injector / Cartridge Set⁶
DUALTEC™ OD655 Injectorfor diopter range +4.0 to +34.0 D
ZEISS R28 IOL Delivery System with ZEISS Z28 Cartridge IOL Delivery System for diopter range +4.0 to +34.0 D
  • 1

    EC-3 Pivotal Clinical Study (FDA IDE study) , n=324, 12 month.

  • 2

    European EC-3 Clinical Investigation, n=96, 6 month, South American EC-3 Clinical Investigation.   

  • 3

    Borkenstein & Borkenstein (2018) Clinical Ophthalmology 2018:12 1219–1227.

  • 4

    Designed to compensate for a range of aberrations, arising from different corneal shapes and lens misalignments. As a result, it provides better imaging quality for real-life conditions.   

  • 5

    For optimized A Constants and ACD Constants refer to IOLCon: www.iolcon.org

  • 6

    Please refer to our web page for the most up-to-date references: www.zeiss.com/injectors