Single-use Lenses for ZEISS RESIGHT with articulated arm holding a fine surgical instrument over a small medical object.
PRODUCT

Single-use Lenses for ZEISS RESIGHT

Uncompromised intraoperative retina visualization

The single-use lenses for the RESIGHT® fundus viewing system from ZEISS provide retinal surgeons with a clear and uncompromised view for every surgical procedure in the posterior segment, while also offering all the advantages of disposable lenses. You will benefit from high-resolution visualization of the far periphery, with high light transmission enabling you to operate under reduced illumination intensity.

  • Clear and detailed view for safe macula surgery
  • Visualization up to the ora serrata
  • Versatility in peripheral surgery
Single-use MACULA LENS for ZEISS RESIGHT with a green handle and a clear round lens, designed by ZEISS.

Clear and detailed view for safe macula surgery

with the MACULA LENS

The single-use MACULA LENS for ZEISS RESIGHT provides high magnification and enhanced contrast compared to other lenses on the market. By combining high resolution with an extensive field of view, the MACULA LENS enhances fundus visualization during macula surgery.

Unlike contact lenses, this single-use MACULA LENS for the ZEISS RESIGHT maintains a non-contact position to the cornea and grants a better view of surgical instruments. The extended working distance to the patient’s cornea prevents the lens from fogging.

 Single-use ULTRA WIDE-ANGLE LENS for ZEISS RESIGHT with a cone-shaped design and a raised pink lever attached.

Visualization up to the ora serrata

with the ULTRA WIDE-ANGLE LENS

With the widest field of view, the single-use ULTRA WIDE-ANGLE LENS for ZEISS RESIGHT enables visualization of the far periphery, up to the ora serrata, reducing the need for tilting and scleral indentation.

With its cone-shaped design, the lens seamlessly integrates into the surgical environment, allowing unobstructed access with instruments. Clinical data confirms reduced condensation throughout the procedure1.

Picture of Prof. Peter Stalmans

With the Single-use Lenses for ZEISS RESIGHT I can operate in a way that is safer for the patient's eye: I could reduce my endoillumination to 10% without compromising the view and with a new ULTRA WIDE-ANGLE LENS, I can remove all the vitreous up to the ora serrata without the need to indent.

Prof. Peter Stalmans Leuven, Belgium
The WIDE-ANGLE LENS for ZEISS RESIGHT with a yellow handle and a large clear lens, designed by ZEISS.

Versatility in peripheral surgery

with the WIDE-ANGLE LENS

The WIDE-ANGLE LENS for ZEISS RESIGHT demonstrates its adaptability across a range of peripheral posterior segment procedures without the need for switching lenses.
 
With its wide-angled, high-resolution view, the lens enables outstanding visualization while effectively preventing condensation for uninterrupted clarity.

ZEISS RESIGHT is shown alongside a monitor displaying a detailed retinal scan.

Smooth workflow and compatibility

All single-use lenses for ZEISS RESIGHT are compatible with any ZEISS ophthalmic microscope and ZEISS integrated intraoperative OCT systems to ensure high-quality retina OCT visualization. Fast and sterile access to a second lens is possible thanks to the lens turret of the ZEISS RESIGHT 500 and ZEISS RESIGHT 700 systems. With just a small turn, you can seamlessly switch lenses during surgery. Thanks to the difference in size and design, you can easily distinguish the different lenses even in dimmed light conditions.

All lenses are delivered in separate sterile packaging, allowing your OR staff to prepare independently for surgery.

Peer perspective

  • No compromise on surgical retinal viewing - Managing retinal detachment Video - Prof. Peter Stalmans

    No compromise on surgical retinal viewing - Managing retinal detachment

  • Professor Peter Stalmans performing a procedure using a ZEISS surgical microscope in a sterile operating room environment.
  • Prof. Peter Stalmans, Leuven, Belgium
    No compromise on surgical retinal viewing - Managing retinal detachment
  • Professor Peter Stalmans
    Single-use Lenses for ZEISS RESIGHT for outstanding intraoperative visualization

Technical specifications

MACULA LENS
WIDE-ANGLE LENS
ULTRA WIDE-ANGLE LENS

Material

Optics: Polymethylmethacrylat (PMMA);
Lens holder: Acrylnitril-Butadien-Styrol Copolymer (ABS)

Optics: Polymethylmethacrylat (PMMA);
Lens holder: Acrylnitril-Butadien-Styrol Copolymer (ABS)

Optics: Polymethylmethacrylat (PMMA);
Lens holder: Acrylnitril-Butadien-Styrol Copolymer (ABS)

Sterilized with

Ethylene oxide

Ethylene oxide

Ethylene oxide

Diameter

~ 23 mm

~ 19 mm

~ 21-26 mm

Get in touch with us!

Receive more information about the product and availability in your country!

Form is loading...

Personal contact information

If you want to have more information on data processing at ZEISS please refer to our data privacy notice

Download

  • Single-use Lenses for RESIGHT Flyer EN

    966 KB



  • 1

    Compared to 128D reusable lens for ZEISS RESIGHT. Data on file.