Microscopic imaging: Mechanobiology Institute at the National University of Singapore (NUS MBI)
Introduction

How cancer finds its way in: Rethinking cancer metastasis with lattice light-sheet microscopy

Selwin Wu, PhD, Principal Investigator of a National Medical Research Council Young Individual Research Grant, and Celestine Ho, MEng, Research Assistant, are leading a team to challenge a long-held idea about how cancer spreads. The familiar picture is simple: Tumor cells push through a barrier. However, their research reveals a more dynamic interaction beyond this barrier: The surrounding tissue actively responds by contracting and eventually tearing. This rupture creates an entry point that facilitates the spread of cancer. The group combines molecular biology, live cell imaging, computational modelling, traction force measurements, and atomic force microscopy. Data from the microscope feeds into simulations that replay the dynamics of invasion. That loop between experiment and model helps connect material science, biophysics, and cancer biology in a single view.

The moment invasion begins

Wu’s team studies how cancer cells invade nearby healthy tissues. The focus is the mesothelium, a thin layer that lines body cavities. Instead of acting as a passive wall, this layer can transmit and generate forces that pull cell junctions apart. The moment of rupture is the moment invasion begins.

Dr. Selwin Wu | Mechanobiology Institute at the National University of Singapore (NUS MBI)

We found that tissues do not just stand there. They react. They pull. They tear. That tearing opens the door for cancer to spread.

Selwin Wu, PhD Principal Investigator, National Medical Research Council Young Individual Research Grant

Lattice Lightsheet 7 in action

  • Ovarian cancer spheroid invasion in mesothelial monolayer

    Ovarian cancer spheroid invasion in mesothelial monolayer. Sample courtesy of Celestine Ho, MEng, Mechanobiology Institute, National University of Singapore
Celestine Ho | Mechanobiology Institute at the National University of Singapore (NUS MBI)

Celestine Ho, MEng, working with the ZEISS Lattice Lightsheet 7 system.

A new way to image

Capturing fast, fragile events inside living tissues is not simple. Researchers need speed, sensitivity, and true three-dimensional information. They also need to avoid phototoxicity that can damage the cells. Earlier approaches forced a choice between clarity and cell health. The study used ZEISS's Lattice light-sheet microscopy to capture three-dimensional changes in living samples over time with reduced phototoxicity.


With Lattice light-sheet imaging, the team observed mesothelial cells separate from the apical surface first. The rupture then spread to the basal side. It was the direct visual proof of tensile fracture in a living tissue.

Lattice light-sheet microscopy allowed us to follow tumor clusters and changes in the surrounding tissue over time, providing a direct view of the rupture process in living samples. 

Selwin Wu, PhD Principal Investigator, National Medical Research Council Young Individual Research Grant

What changed in the science

The images challenged a widely held belief about cancer invasion. Prior to the rupture, there were few protrusions from the invading ovarian cancer cells. The critical factor was not only the aggressive advance of these cells, but also the mechanical failure of the surrounding tissue itself.

 

Celestine Ho | Mechanobiology Institute at the National University of Singapore (NUS MBI)

Now we ask different questions. Not just if invasion happens, but how it starts, when it starts, and where it starts.

Celestine Ho, MEng Research Assistant

Broader impact beyond a single lab

Clear, low phototoxicity time lapse videos helped the team attract collaborators in Hong Kong and Europe. The same visuals supported successful proposals to Singapore’s National Medical Research Council. Students in the lab now take part in quantitative analysis that turns striking images into measurable insight.

As the only ZEISS Lattice Lightsheet users in Southeast Asia, Wu and Ho are helping position Singapore as a hub for advanced live cell imaging in the region. “We appreciate the technical support provided by the ZEISS team in Singapore for the lattice light-sheet imaging used in this work", says Wu.

This research is funded by a National Medical Research Council Young Individual Research Grant, with Selwin Wu, PhD, as Principal Investigator. The findings are published in Developmental Cell:

Wu, S.K., Sun, F., Ho, C.Z., et al. (2026). Multiscale mechanisms driving tissue rupture by invading cells. Developmental Cell 61(4), 787-803.e8. https://doi.org/10.1016/j.devcel.2026.01.016

The study is highlighted in a Developmental Cell Preview: Wimalasena, V.K., and Ewald, A.J. (2026). Active wetting and mechanics of collective cancer invasion. Developmental Cell 61(4), 716-717.
https://www.cell.com/developmental-cell/fulltext/S1534-5807(26)00119-X

The team will test whether the same tearing mechanism appears in other tissues and in other diseases. If it does, new strategies open up. Therapies could aim to reinforce tissue barriers or block the molecular triggers that cause rupture. The goal is simple. Slow the spread of cancer or prevent it altogether.
 

Live ovarian cancer spheroid and mesothelial cells: Maximum intensity projections of ovarian cancer spheroids (green) and mesothelial cells (red)

The image that stays with you

Asked how she would explain the work to a non-scientist, Ho does not hesitate. She would show a single clip. Two cells, joined like links in a chain, pulled apart until the contact shreds. That is the moment a cancer breaks through. Thanks to lattice light-sheet microscopy, that moment is no longer hidden.

In brief

  • The traditional view is that cancer cells actively push through tissue barriers. This research shows the process is more of a two-way interaction — the surrounding healthy tissue doesn't just stand there; it contracts, generates forces, and ultimately tears, creating an opening that cancer cells can exploit. The tissue failure itself, not the aggressiveness of the tumor cells, is the critical trigger.

  • Capturing fast, delicate events inside living tissue requires speed, sensitivity, and true 3D resolution — all without damaging the cells. Earlier methods forced a trade-off between image quality and cell health. Lattice light-sheet microscopy provided the spatial and temporal resolution required to observe tumor clusters and surrounding cells during the rupture process, with reduced phototoxicity. The study used a ZEISS Lattice Lightsheet 7 system for these experiments. This means researchers can follow tumor clusters over time without the imaging process itself disrupting or harming the biological events they're trying to observe — allowing researchers to follow these biological events in living samples over time. 

  • If the same tissue-tearing mechanism is found in other cancer types and tissues, it could open entirely new therapeutic avenues — for example, therapies designed to reinforce tissue barriers or block the molecular signals that trigger rupture, rather than only targeting the cancer cells themselves.