Verifying refractive outcomes and ensuring long-term reliability
challenge

Check

Verifying refractive outcomes and ensuring long-term reliability

Increasing patient expectations for long-term reliable outcomes

Clinical challenge

As the average age of cataract patients is declining1, surgeons need to cater to increasing patient expectations and provide long-term solutions.2

Yet, particularly after the removal of hard cataracts, higher rates of inflammation and edema can be experienced.3 In the long-run, dislocated IOLs or dysphotopsias4 may cause headaches  – both to the surgeon and the patient.

Traumatic coloboma of the iris

Traumatic coloboma of the iris

Reliability in post-op check up and long-term refractive outcomes

Clinical solution

As the extraction of hard cataracts is associated with higher post-op complications, thorough post-operative diagnostics are vital.3 Trusted technologies are slitlamp and OCT. To ensure life-long tolerability of the implant as well as an excellent patient outcome, an optimal IOL needs to be chosen. Hydrophilic IOLs have a great biocompatibility which is especially important in eyes with a damaged blood-aqueous barrier (from uveitis, glaucoma, diabetes).5

Additionally, inflammatory cells accumulate less easily on hydrophilic IOLs than hydrophobic IOLs. Dysphotopsias also occur less in hydrophilic lenses, as they have a lower refractive index compared to hydrophobic IOLs.6 Specifically IOLs with a 4-point haptic design are a trusted platform for excellent centration and stability in the bag.7

Premium optical quality – ZEISS IOL technology and post-op diagnostic device

ZEISS solution

The ZEISS CT ASPHINA family, one of the most implanted IOLs in the ZEISS hydrophilic IOL portfolio, provides predictable and stable refractive results. The SL 800 slit lamp from ZEISS equips you with an all round setup for the observation of anterior and posterior segments.

ZEISS CT ASPHINA 409M/MP

ZEISS CT ASPHINA 409M/MP

The ZEISS CT ASPHINA 409 is designed for quick unfolding and self-centering after implantation, providing you confidence in the outcome of the procedure.

  • Reliable 4-point haptic design developed to provide predictive outcomes due to its self-centering ability
  • Suitable for patients regardless of their corneal shape and pre-existing lens conditions
  • Does not induce spherical aberration
ZEISS SL 800 and SL Imaging Solution

ZEISS SL 800 and SL Imaging Solution

  • The VarioLight cold white feature benefits scattering and helps to identify irregularities within the anterior segment
  • High-quality images and video captures can be added to exam reports to offer you the ability to compare and document cases
  • 1

    Marketscope 2016.   

  • 2

    http://corporate.ewreplay.org/?v=6122663037001

  • 3

    S.Garg, Surgeons meet challenges of removing rock-hard cataracts, Ocular Surgery News 2018, https://www.healio.com/news/ophthalmology/20181010/surgeons-meet-challenges-of-removing-rockhard-cataracts.

  • 4

    R. J. Olson, MD, Salt Lake City, Review of Ophtalmology, PUBLISHED15 JANUARY 2005 Demystifying Dysphotopsia.

  • 5

    A New-Generation Hydrophilic Acrylic IOL, STEVEN D. VOLD, MD CRSTEurope, 2011; Abela-Formanek C, Amon M, Schild G, Schauersberger J, Heinze G, Kruger A. Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses. J Cataract Refract Surg. 2002;28(1):50-61; Abela-Formanek C, Amon M, Kahraman G, Schauersberger J, Dunavoelgyi R. Biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses in eyes with uveitis having cataract surgery: Long-term follow-up. J Cataract Refract Surg.2011;37(1):104-12.   

  • 6

    J. T. Holladay and M. J. Simpson, “Negative dysphotopsia: Causes and rationale for prevention and treatment,” J. Cataract Refract. Surg., 2017.   

  • 7

    Ganesh and Brar, 2017. Long-term visual outcomes and patient satisfaction following bilateral implantation of trifocal intraocular lenses. Clinical Ophthalmology. 2017:11 1453-1459 ** P. Mojzis et. al.: Implantation of a diffractive trifocal intraocular lens: One-year follow-up. Journal of Cataract and Refractive Surgery; August 2015. Volume 41, Issue 8, Pages 1623-1630.

  • 8

    U. Devgan, Dense brunescent cataracts present surgical challenges, Ocular Surgery News 2011, https://www.healio.com/news/ophthalmology/20120331/dense-brunescent-cataracts-present-surgical-challenges.

  • 9

    S.Garg, Surgeons meet challenges of removing rock-hard cataracts, Ocular Surgery News 2018, https://www.healio.com/news/ophthalmology/20181010/surgeons-meet-challenges-of-removing-rockhard-cataracts.

  • 10

    A.Brissette, OCT Is Indispensable for Pre-op Cataract Evaluation, Opthalmology Management 2019, https://www.ophthalmologymanagement.com/newsletters/insights-into-integrated-diagnostic-imaging/may-2019.

  • 11

    M. Colvard, Phacoemulsification of the rock hard cataract, Eyeworld 2012, https://www.eyeworld.org/article-phacoemulsification-of-the-rock-hard.